NPM-W 2 EJM7DE-MB-07 O-00 7-1-2 -4 Setting information 3 System administration T ype Item Description Initial value Setting range Determine LW16-filter ultimate detect data This is a criterion for detecting filter cl ogg…

100%1 / 714
NPM-W2 EJM7DE-MB-07O-00
Unit
setting
Action parameter
setting 2
7-1-2-3
Setting information 2
Operating procedure
7-1-2
Head (1/2)
Type Item Description Initial
value
Setting
range
Mechanic
Placement down
2nd speed
(Standard) [mm/s]
The lowering speed on the 2nd step when
moving down two steps for placement.
For the 3-nozzle head only
10
3.0 to
100.0
Placement down
2nd speed (Low)
[mm/s]
The lowering speed on the 2nd step when
moving down two steps for placement under
a placement load.
For the 3-nozzle head only
5
3.0 to
100.0
Placement 2nd up
1st speed [mm/s]
The rising speed on the 1st step when
moving up two steps for transcription/
placement of a transcription
component.
For the 3-nozzle head only
5
3.0 to
100.0
Determine
Bad nozzle error
rate [%]
This is a criterion used to judge nozzles
good or bad.
The nozzle whose error rate has reached
this value or more is determined to be a bad
nozzle, which will not be used in automatic
operation.
20
0.1 to
100.0
Bad head error
rate
[%]
This is a criterion used to judge heads good
or bad.
The head whose error rate has reached this
value or more is determined to be a bad
head, which will not be used in automatic
operation.
For 8/3-nozzle heads only
20
1.0 to
100.0
Nozzle clean
quantity [piece]
Set the frequency with which the nozzles
are cleaned during automatic operation.
When the production count reaches this
value, a forced blow cleans the nozzles of
heads.
0 0 to 200
XY unit (2/2)
Type Item Description Initial
value
Setting
range
Determine
Time-lapse change
calibration interval
threshold[mm]
If the amount of deviation relative to the previous
measurement result exceeds the setting value,
shorten the interval time. The interval time is
lengthened if it does not exceed the setting value.
1
0.01 to
1.50
Time-lapse change
calibration error
threshold[mm]
If the amount of deviation relative to the previous
measurement result exceeds the setting value,
the machine comes to a single error stop.
1.5
0.01 to
1.50
NPM-W2 EJM7DE-MB-07O-00
7-1-2-4
Setting information 3
System
administration
Type Item Description Initial
value
Setting
range
Determine
LW16-filter ultimate
detect data
This is a criterion for detecting filter clogging.
If, in filter clogging check, the vacuum
sensor value has exceeded this value, the
filter is determined to be clogged.
For light weight 16-nozzle head only
-80 -100 to 0
12-nozzle head
filter clogging
detection value
This is a criterion for detecting filter clogging.
If, in filter clogging check, the vacuum
sensor value has exceeded this value, the
filter is determined to be clogged.
For 12-nozzle head only
-80 -100 to 0
8-nozzle head filter
clogging detection
Value
This is a criterion for detecting filter clogging.
If, in filter clogging check, the vacuum
sensor value has exceeded this value, the
filter is determined to be clogged.
For 8-nozzle head only
-84 -100 to 0
3-nozzle head filter
clogging detection
Value
This is a criterion for detecting filter clogging.
If, in filter clogging check, the vacuum
sensor value has exceeded this value, the
filter is determined to be clogged.
For 3-nozzle head only
-90 -100 to 0
After ejecting adhesion
check parts size
After component is ejected, if the larger
component size of either L or W is less than
the value, and if it is reflection component,
the ejection OK component is checked for
multi-recognition camera adhesion to detect
ejection error.
0.0
0.0 to
150.0
Head (2/2)
NPM-W2 EJM7DE-MB-07O-00
7-1-2-5
Setting information 4
Unit
setting
Action parameter
setting 3
Operating procedure
7-1-2
Type Item Description Initial
value
Setting
range
Mechanic
Interval Y of dummy
dispensing on tape
[mm]
Set the interval of dummy dispensing on
tape in the Y direction.
For the dispensing head only
1.00 1.00 to 5.00
Determine
Tape break warning
length [mm]
When the length of the tape on the dummy
dispensing unit becomes shorter than this
set value, the dummy dispensing tape is put
in a maintenance warning state.
The number of times of dummy dispensing
tape feed is counted, and the remaining tape
length is determined.
Tape length: About 6 m
Tape length per feed: About 8 mm
For the dispensing head only
1000.0
500.0 to
3000.0
Action temp diff warn
judge value()
While the option setting of “Temperature
warning check” is set to ON, being compared
with the temperature set in the temperature
controller unit and the current temperature,
the value (temperature difference) to display
a warning is decided
Temperature warning check is activated
while the following operations are performed.
At the start of production
When [Eject Confirm] on the nozzle screen in
‘Changeover’ – ‘Component Preparation’ is
pressed.
When [Teach start] on the teach dummy
screen in ‘Production data’ is pressed.
For dispensing head only
52 to 10
Dispensing head
Conveyor(1/4)
Type Item Description Initial
value
Setting
range
Mechanic
PcbRecogErrInchingVa
lue[mm]
The area where the inching operation is
enabled on an PCB recognition error.
50to 20
Support pin keep
number[pin/Lane]
(Lane1)
The number of support pins being present in
the machine (Lane1)
Displayed when automatic change
specifications are selected for the support pin
00 to 20
Support pin keep
number[pin/Lane]
(Lane2)
The number of support pins being present in
the machine (Lane2)
Displayed when automatic change
specifications are selected for the support pin
00 to 20
Decelerate adjust
value[mm]
Set this value if a PCB is easy to slip out during
transport due to PCB material matter.