NPM-W2 EJM7DE-MB-07O-00
If vacuum check has completed successfully
[Check vacuum complete] is displayed in .
If vacuum check failed to complete
successfully
The background of the measured value of the
corresponding nozzle is displayed in yellow.
Unit
adjust-
ment
Action check of the
placement head
7-2-6-1
You can collectively check whether the actions of the placement head or nozzles are normal.
Perform on both and .
Operating procedure
7-2-6
1
+
A B
C D
A
B
C
F
E
F
2
1
D
E
F
(The vacuum check result of each nozzle
is displayed)
Nozzle
A number of a nozzle attached to the
placement head.
”-” is displayed if any nozzle is not
attached.
Sensor value
If the measured value is abnormal, its
background is shown in yellow.
Full
Filter clogging detection value. Check
if the measured value is abnormal as
the result of [Filter cleaning].
The previous or next table
is displayed.
Err.
Nozzle clogging detection value.
Check if the measured value is
abnormal as the result of [Vacuum
check].
Message display area
NPM-W2 EJM7DE-MB-07O-00
If air blow and the vacuum pressure
measurement results in error
Confirm the message
(The background of the measured value
of the corresponding nozzle is
displayed in yellow.)
7-2-6-2
+
2
(Air blow and the vacuum pressure of
each head (nozzles are removed) are
measured)
System
administration
If air blow and vacuum pressure
measurement completes without error
[Cleaning blow complete] is displayed
in .
F
NPM-W2 EJM7DE-MB-07O-00
Unit
adjust-
ment
Vacuum output check
(placement head)
7-2-7
1
You can change the valve and check whether each of the vacuum pumps and air blows operates normal
individually.
+
1
+
+
+
BA C
A
B
C
BC
Operating procedure
7-2-7
Air flow value
Nozzle air flow value.
Check the air flow value during
vacuuming or blowing
To turn ON/OFF the vacuum pump
(The vacuum pump is switched ON/OFF)
With the vacuum pump turned ON, to
turn ON/OFF only the vacuum valve
of a specified nozzle
(The vacuum pressure is displayed in the
field below)
With the vacuum pump turned ON,
to turn ON/OFF only the vacuum
break valve of a specified nozzle
(The pressure for the vacuum break is
displayed in the field above)
To turn ON/OFF the cleaning blow
(The cleaning blow valve is switched
ON/Off)
Vacuum valve
Vacuum break valve
, in 7-2-6 is displayed in
terms of 8-bit.
B
B
C
“Sensor value” “Full”
Perform on both and .