N7201A616E00_0317.pdf - 第558页
NPM-W 2 EJM7DE-MB-07 O-00 7-1-2 -5 Setting information 4 Unit setting Action par ameter setting 3 Operating procedure 7-1-2 T ype Item Description Initial value Setting range Mechanic Interval Y of dummy dispensing on ta…

NPM-W2 EJM7DE-MB-07O-00
7-1-2-4
Setting information 3
System
administration
Type Item Description Initial
value
Setting
range
Determine
LW16-filter ultimate
detect data
This is a criterion for detecting filter clogging.
If, in filter clogging check, the vacuum
sensor value has exceeded this value, the
filter is determined to be clogged.
●For light weight 16-nozzle head only
-80 -100 to 0
12-nozzle head
filter clogging
detection value
This is a criterion for detecting filter clogging.
If, in filter clogging check, the vacuum
sensor value has exceeded this value, the
filter is determined to be clogged.
●For 12-nozzle head only
-80 -100 to 0
8-nozzle head filter
clogging detection
Value
This is a criterion for detecting filter clogging.
If, in filter clogging check, the vacuum
sensor value has exceeded this value, the
filter is determined to be clogged.
●For 8-nozzle head only
-84 -100 to 0
3-nozzle head filter
clogging detection
Value
This is a criterion for detecting filter clogging.
If, in filter clogging check, the vacuum
sensor value has exceeded this value, the
filter is determined to be clogged.
●For 3-nozzle head only
-90 -100 to 0
After ejecting adhesion
check parts size
After component is ejected, if the larger
component size of either L or W is less than
the value, and if it is reflection component,
the ejection OK component is checked for
multi-recognition camera adhesion to detect
ejection error.
0.0
0.0 to
150.0
■Head (2/2)

NPM-W2 EJM7DE-MB-07O-00
7-1-2-5
Setting information 4
Unit
setting
Action parameter
setting 3
Operating procedure
7-1-2
Type Item Description Initial
value
Setting
range
Mechanic
Interval Y of dummy
dispensing on tape
[mm]
Set the interval of dummy dispensing on
tape in the Y direction.
●For the dispensing head only
1.00 1.00 to 5.00
Determine
Tape break warning
length [mm]
When the length of the tape on the dummy
dispensing unit becomes shorter than this
set value, the dummy dispensing tape is put
in a maintenance warning state.
The number of times of dummy dispensing
tape feed is counted, and the remaining tape
length is determined.
・Tape length: About 6 m
・Tape length per feed: About 8 mm
●For the dispensing head only
1000.0
500.0 to
3000.0
Action temp diff warn
judge value(℃)
While the option setting of “Temperature
warning check” is set to ON, being compared
with the temperature set in the temperature
controller unit and the current temperature,
the value (temperature difference) to display
a warning is decided
Temperature warning check is activated
while the following operations are performed.
・At the start of production
・When [Eject Confirm] on the nozzle screen in
‘Changeover’ – ‘Component Preparation’ is
pressed.
・When [Teach start] on the teach dummy
screen in ‘Production data’ is pressed.
●For dispensing head only
52 to 10
■Dispensing head
■Conveyor(1/4)
Type Item Description Initial
value
Setting
range
Mechanic
PcbRecogErrInchingVa
lue[mm]
The area where the inching operation is
enabled on an PCB recognition error.
50to 20
Support pin keep
number[pin/Lane]
(Lane1)
The number of support pins being present in
the machine (Lane1)
●Displayed when automatic change
specifications are selected for the support pin
00 to 20
Support pin keep
number[pin/Lane]
(Lane2)
The number of support pins being present in
the machine (Lane2)
●Displayed when automatic change
specifications are selected for the support pin
00 to 20
Decelerate adjust
value[mm]
Set this value if a PCB is easy to slip out during
transport due to PCB material matter.
0 0 to 100

NPM-W2 EJM7DE-MB-07O-00
7-1-2-6
Setting information 5
System
administration
■Conveyor(2/4)
Type Item Description Initial
value
Setting
range
Timer
PCB in confirm time [s]
If, keeping the PCB request signal sent to the
upstream equipment, the machine comes to a
single stop during production, it drops the
request signal and stops loading a PCB of
certain size that cannot be loaded to the
standby position.
Taking into account the possible presence of a
PCB being unloaded, this sets the time for
loading confirmation after dropping of the
request signal.
When single stop is detected in large board
transport, convey is ended if it has not reached
the tip sensor after READY-OFF.
10 to 5
PCB eject waiting
time(After Require Off)
[s]
The time that elapses after the PCB request
signal from the downstream equipment is
turned off and before the conveyor stops during
the PCB ejection process.
After post process equipment has READY-OFF,
move to the carry-out completion process after
setting time.
●It is the ability to extend the READY-ON time
after post process equipment in a simulated
manner.
0 0 to 100
PCB eject waiting
time(Require Off) [s]
The time limit that elapses after the start of
PCB ejection and before the PCB request
signal is turned off.
After post process equipment has READY-OFF,
it is judged as time out if the carry-out process
does not complete even over setting time.
10 5 to 100
PCB in waiting time
[s]
The time limit that elapses after the start of
PCB loading and before a PCB sits at the PCB
standby position.
10 5 to 100
PCB move waiting
time [s]
The time limit for a PCB to travel inside the
machine.
10 5 to 100
Z-clamp release
waiting time [ms]
The minimum waiting time that elapses after
the Z clamp releases a PCB and before the
transfer motor spins.
0 0 to 5000
PCB in confirm time
before carry in again[s]
The time limit for completing transfer when
there is a PCB being transferred on the
reloading conveyor.
5 0.0 to 60.0