YSM10安装调整(eng).pdf - 第11页

For Ser v ice E n gineer Service Information SI1610004E -000= YSM10_Proced ures for the adjustmen ts required after installing a machine 11/107  Work procedure 1. Figure 4 2. 3. Figure 5 4. Figure 6 5 󴥔 该文档 是 极速PDF 编辑器…

100%1 / 107
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
10/107
3.3 When the monitor interferes with the adjoining machine 󴙔󵷒󷃇󳵩
󴳷
YSM10
󵷗
Figure 3
󶿆󶿆󶿆 󶙯󶙯󶙯
󶗅󶗅󶗅 󶿆󶿆󶿆
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
11/107
Work procedure
1.
Figure 4
2.
3.
Figure 5
4.
Figure 6
5 󴥔
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
12/107
3.4 Connect to the power source and air supply
Caution:
Connections of the power and air supply
Figure 7
Specifications of the power and air supplies
Item
Specifications
󳪌󳪌󳪌
0.45MPa (4.5Kgf/cm
2
)
Set pressure:
0.40 ~ 0.41MPa
@@@@@@@@@@@󵖑󵖑󵖑
& 󷾒󵪈
Three-phase AC 200/208/220/240/380/400/416V
+/-10% 50/60Hz
Power capacity
󴕴󳹈
1.0kW
󳚜󵰶󵰶󶘇
Conductor cross-section area: 4 mm
2
or more
Table 10
to 0.40 ~ 0.41Mpa󷜛󷛈
.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/