For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
55/107
6. “ACP-Station” adjustment (with a QFP and the Multi camera)
After completing the “ACP-Chip” adjustment by using the Multi camera and 1005 ceramic chip
components, perform the accuracy adjustment for each with the “ACP-Station” utility by
mounting a QFP on the FAMF station.
304A(315A) 68-pin QFP
307A(318A) 208-pin QFP
:
When the machine is equipped with the Multi camera, 304A(315A) s and 307A(318A) s,
perform the ACP-Station adjustment.
Also, when the customer has the required s and the head that the is to be attached is
determined, perform the adjustment.
6.1 General description of the “ACP-Station” adjustment
No special board data is required for the adjustment as “MCH_SETUP.ygx.” is used as the board
data.
The “ACP-Station” utility provides the following features:
All the heads, cameras and s can be adjusted consecutively
In the “ACP-Station” utility, you can perform the adjustment for all the heads, cameras and s
consecutively once you complete the initial setting.
Automatic feedback
In the “ACP-Station” utility, the mounting accuracy is judged automatically to determine whether to
perform feedback or not.
Minimum amount of components are required for the adjustment
The minimum amount of components necessary for the adjustment is statistically calculated, which
enables the adjustment to be performed with fewer components and reduces the time for the
adjustment process.
The function that copies the accuracy parameters
The adjustment results of the main camera are reflected to the other cameras automatically, which
reduces the time to adjust the other cameras.
该文档是极速PDF编辑器生成,
如果想去掉该提示,请访问并下载:
http://www.jisupdfeditor.com/

For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
56/107
6.2 Required jigs
Table 28
Board data
Read the board data (MCH_SETUP.ygx) and check the version of the data in the “Board
Comment” field on the [Board]–[Board] window.
Required version: Ver.1.058 or later
:
Make sure to read the board data before the adjustment as the “Mark Information”, “Part Information”
and the “Board Information (Board size X, Y and Z) of the board data “MCH_SETUP” will be used for
the ACP-Station adjustment.
Item
Part Name
Part No.
Qty
FAMF Station
(Plate size: 240x170)
FAMF STATION
ASSY.
KGA-M88F0-A0
1
(Use either of
the stations.)
Small FAMF Station
(Plate size: 100x100)
FAMF STATION
S.ASSY.
KGA-M88F0-B0
68-pin QFP
QFP 68P
KW8-M880A-10
1
208-pin QFP
(With the sticker)
QFP 2S
KM0-M880A-20
1
该文档是极速PDF编辑器生成,
如果想去掉该提示,请访问并下载:
http://www.jisupdfeditor.com/

For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
57/107
6.3 Flow of the adjustment
Perform initial setup for using the FAMF station (Connect the air supply and wirings for the ejector),
check the settings for the “ACP-Station” adjustment and
[All] to start the adjustment.
Figure 73
Initial setup for the FAMF station
Check the board data
• Block fiducial
• Mounting coordinate
• Mark recognition (Fiducial mark,
QFP mark)
• Part recognition (68-pin QFP)
Start up CalibSm – “ACP-Station”
Run the program
<When the adjustment cannot be
completed properly>
Identify the cause and take appropriate
measures, and perform the adjustment again.
Read the board data (MCH_SETUP)
Check the Total Index
Setting on the right side of the window
Check the Board data
Setting on the left side of the window
Check the setting on the left
side
Main camera
Adjust camera
Adj. Setting and Head
Check the setting on the right
side
Speed
Mark
UtclXY
Storage Pos XY
Block No.
Set the QFP on the storage
position
该文档是极速PDF编辑器生成,
如果想去掉该提示,请访问并下载:
http://www.jisupdfeditor.com/