For Ser v ice E n gineer Service Information SI1610004E -000= YSM10_Proced ures for the adjustmen ts required after installing a machine 47/107 4. Start the “ ACP-Chip ” mea surement. W hen th e [Save] is tapped , the ad…

100%1 / 107
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
46/107
5.5.2 Mounting, measurement and correction by the ACP-Chip
When completing the initial setup and the necessary settings, start the ACP-Chip adjustment.
This section describes how to perform the adjustment by tapping the [All]
on the “ACP-Chip
window.
1.
[Reset] .
When performing the adjustment after newly installing a machine,
[Reset] before
tapping the [All]
.
2.
[All] on the AutoRun/Measure tab.
After checking the settings for the ACP-Chip adjustment and completing the initial setup for the 󵪼
󵮄 board,
[All] .
Figure 58
3. Enter the name of the file for saving the measurement results.
[All] to display the window for entering the name of the file that the measurement
results are to be saved in.
Figure 59
:
~ Name of the file for saving the adjustment data ~
The file is named to indicate the adjustment method and the items to be adjusted as default. Save it in
the folder with the name of the date that the folder is created.
The “Date folder” (folder with the name of the date that the folder is
created) is created automatically under the
“D:¥Machine¥Result¥ACPResult” folder.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
47/107
4. Start the ACP-Chip measurement.
When the [Save]
is tapped, the adjustment and then the measurement are performed
continuously.
Figure 60
5. Check the AMF Index 1 and AMF Index 2 values.
When the measurement has been completed, the AMF Index window appears.
Fill in the values on the Check sheet as the values before the feedback
If the AMF Index 1 value is 1.0 or above, it indicates that the mounting accuracy meets the
specification.
:
If the AMF Index is 1.0 or above, the ACP-Chip adjustment for the main camera (Scan camera) is
completed.
If the machine is equipped with the multi camera, go on to 5.6 ACP-Chip adjustment for the Multi
camera (Option).
Figure 61
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
48/107
5.5.3 Feed back the correction values when the “AMF Index 1“ falls below 1.0
When the “AMF Index 1” falls below 1.0, the accuracy does not meet the specification. Feed back
the correction values and perform the ACP-Chip measurement again.
:
As the camera position adjustment for the component recognition cameras and the Head offset
adjustment have been performed before performing the ACP-Chip adjustment, just feed back the
correction values to enhance the accuracy.
1. Check the VgChart window.
Check if any of the heads is the cause for the insufficient accuracy on the VgChart.
If an abnormarity is observed on a speficied head, check the following for the head.
Is the 󳬹󳴵 attached to the head properly?
Are the leaf springs straight (not bent) or installed properly?
Is the spring at the tip of the 󳬹󳴵 moves properly?
If the 󳬹󳴵 contaminated or chipped?
:
See “5.7.2 Check the “VgChart” window” for how to interpret the VgChart.
2. Select the “Accuracy Value” tab.
Select the “Accuracy value” tab to display the parameters to be corrected according to the
measurement results.
Figure 62
3. [Save Mch.Data] .
After checking the values to be corrected, [Save Mch.Data] .
4. Perform the accuracy check after feeding back the correction values.
After saving the correction values in the machine data, perform mounting and measurement by the
ACP-Chip, and perform the accuracy check again.
When the AMF Index 1 after the correction is 1.0 or above (OK)
Fill in the Index value after the adjustment as the “Data after feedback” on the check sheet.
* If the machine is not equipped with a multi camera, this is the end of the accuracy adjustment
process.
When the AMF Index 1 after the correction falls below 1.0 (NOT OK)
After feeding back the correction values by tapping the [Save Mch.Data]
, perform the
ACP-Chip accuracy check again.
:
If the “AMF Index 1” value is NOT 1.0 or above even after feeding back the correction values twice or
more, perform 11. Basic adjustments required when “AMF index 1” falls below 1.000. (<Basic
adjustments 1> in YSM10 Installation Check sheet.)