YSM10安装调整(eng).pdf - 第60页

For Ser v ice E n gineer Service Information SI1610004E -000= YSM10_Proced ures for the adjustmen ts required after installing a machine 60/107 4. Display the “ I/O ” w indow to check the operation of the ejector. Select…

100%1 / 107
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
59/107
6.5 Initial setup for the FAMF station
Connect the air supply and wiring for the FAMF station.
6.5.1 When using a standard FAMF station
1. Connect the air supply to the ejector.
Connect the air hose of the ejector for the FAMF station (
mm) to the air joint (
mm) at the left
side of the feeder bank.
Figure 75
2. Connect the connector of the ejector.
Take out the harness for driving the ejector AMF1 from the duct on the left of the feeder bank,
and connect it to the ejector connector.
Figure 76
3. Clamp the FAMF station board.
1) Connect the
6.0 mm air hose from the ejector to the air joint on the back of the station.
2) Change the conveyor width to 170.0mm,
[Main Stopper] and the [Board clamp]
to clamp the station with the board clamp.
Figure 77
AMF1 connector
[Caution]
Make sure that the air hose of the
ejector for the station is located under
the conveyor to avoid interference with
the head.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
60/107
4. Display the I/O window to check the operation of the ejector.
Select the [Unit] and the “I/O” tab. Select “OTHERS” from the “Output” pull-down menu.
:
When the ejector is connected to “AMF 1”, select [T01000D5].
Figure 78
5. Make sure that the ejector operates properly.
1) Check the operation of the ejector by turning ON the output “T01000D5.
2)
[ON/OFF] to make sure that the suction is active in the center hole of the
FAMF station.
6.5.2 When using a small FAMF station
The following is the procedure for how to change the setting when using a small FAMF station
(100x100).
1) Change the conveyor width to 100.0mm. (Board Size Y does not need to be changed.)
2) Change the setting of Mount No. on the ACP-Station window (CalibSm) from 1 to 2.
Figure 79
Table 29
FAMF station
Mount No.
Local Fiducial
Standard (240X170mm)
1
1
Small (100X100)
2
2
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
61/107
6.6 Check the board data
Use some information of the board data MCH_SETUP.ygx to perform the ACP-Station
adjustment.
6.6.1 Information required for the adjustment
* The coordinates shown in this document are the default values.
Mounting coordinate X, Y
X, Y coordinates of Board Offset and Block Offset
X, Y coordinates and Mark number of Local on the [Board]-[Fiducial] window
1. Check the mounting coordinate X, Y.
Use the X, Y coordinates of the mounting coordinate No.1 (on the Mount tab) as the coordinate
for mounting a component in the center of the station (Size: 240x170mm). When using a small
station (Size: 100x100) for the adjustment, use the coordinate No.2.
Do not change the X and Y coordinates.
The R coordinate and the Part number are not used here as they are set in the ACP-Station
utility.
Figure 80
2. Check the X, Y coordinates of Board Offset and Block Offset.
The coordinate of the block origin to be used varies depending on the conveyor specification of the
machine. Make sure that the block origin corresponds to the conveyor specification of the machine.
Set the same block origin number on the ACP-Station window in the adjustment utility.
Figure 81
Caution:
DO NOT change the Board Offset coordinate as it is used in other adjustment utilities.
If the block origin is off the position, check if the board is clamped properly, and the edge clamp
coordinate is appropriate.
When a small FAMF station is
used, select No.2.
Use 2 as the local fiducial.