For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
53/107
5.7.3 How to analyze the VgChart
Refer to the following for the typical charts of the adjustment result
and how to take measures.
A. If the XY offset shift is found in the mounting result data
What is XY offset shift?
The components are mounted with deviation to the same direction
in all angles, as can be seen in Figure 71.
In this case, the Index 2 value may be 1.00 or above.
Figure 71
:
Even when the “Index 1” value falls below 1.000, there is a case that the mounting positions are close
to one another, and are all deviated in the same way.
When this symptom occurs, there is a possibility that the positional coordinates of the fiducial camera
has been changed. Make sure that the camera is positioned properly before performing feedback.
B. If the mounting result data spreads in the X and Y directions
The mounting result data may spread in the X and Y directions in different ways depending on
the mounting angle as can be seen in Figure 72.
The Index 2 value varies depending on the pattern of the mounting result data.
When this symptom occurs, any of the basic data may have been changed.
When the symptom still occurs even after feeding back the correction values, perform the basic
adjustments again.
Figure 72
:
When the Index 1 value is 1.000 or above and the Index 2 value falls below 1.000, there is a case
that the mounting result data slightly spreads in the X and Y directions. In this case, feed back the
correction values instead of readjusting the basic data.
When any problem related to mounting inaccuracy is found, take appropriate measures and perform
the readjustment.
Items of the basic data to be adjusted
Perform the adjustment for the following items:
Fiducial camera - 󴥬󴫐 adjustment
Scan camera - 󴥬󴫐 adjustment
Head Offset Z adjustment
When the machine is equipped with the Multi camera
After completing the basic adjustments for the scan camera, the basic data of the Multi camera
needs to be adjusted.
Perform the 󴥬󴫐 adjustment for the Multi camera.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
54/107
C. If the variation and abrupt shift are found in the mounting result
If the mounting state is unstable, accurate measurement data cannot be obtained. Therefore, the
mounting result cannot be improved no matter how many times the feedback is performed.
Identify the cause of the problem and take appropriate measures.
[Items to be checked]
Is the board clamped properly?
Does the component reach the board surface properly when it is being mounted?
Is the mark recognition performed in the stable condition?
(The mark should be clean and the mark information should be correct.)
Is the component supply unit feeding the component properly, and the components are
picked up properly?
Are the components recognized properly?
Is the 󳬹󳴵 clean or secured properly?
Are the lens of the camera and the lighting part clean?
Is the camera mounted to the machine properly?
If any problems are detected, take appropriate measures and perform the ACP-Chip adjustment
again.
When performing the adjustment of the board edge clamp unit, the data of the following items
may need to be adjusted.
[Items to be adjusted]
PCB Height
Head Offset Z
Caution:
The 󴥬󴫐 adjustment for the fiducial camera needs to be performed only when the AMF Index 1 falls
below 1.000 with the main camera (for recognizing components).
If the AMF Index 1 falls below 1.000 when checking the mounting accuracy with the sub camera, the
adjustment is not required.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
55/107
6. ACP-Station adjustment (with a 󵪼󵮄 QFP and the Multi camera)
After completing the ACP-Chip adjustment by using the Multi camera and 1005 ceramic chip
components, perform the accuracy adjustment for each 󳬹󳴵 with the ACP-Station utility by
mounting a 󵪼󵮄 QFP on the FAMF station.
304A(315A) 󳬹󳴵 68-pin 󵪼󵮄 QFP
307A(318A) 󳬹󳴵 208-pin 󵪼󵮄 QFP
:
When the machine is equipped with the Multi camera, 304A(315A) 󳬹󳴵s and 307A(318A) 󳬹󳴵s,
perform the ACP-Station adjustment.
Also, when the customer has the required 󳬹󳴵s and the head that the 󳬹󳴵 is to be attached is
determined, perform the adjustment.
6.1 General description of the ACP-Station adjustment
No special board data is required for the adjustment as MCH_SETUP.ygx. is used as the board
data.
The “ACP-Station” utility provides the following features:
All the heads, cameras and 󳬹󳴵s can be adjusted consecutively
In the “ACP-Station” utility, you can perform the adjustment for all the heads, cameras and 󳬹󳴵s
consecutively once you complete the initial setting.
Automatic feedback
In the “ACP-Station” utility, the mounting accuracy is judged automatically to determine whether to
perform feedback or not.
Minimum amount of components are required for the adjustment
The minimum amount of components necessary for the adjustment is statistically calculated, which
enables the adjustment to be performed with fewer components and reduces the time for the
adjustment process.
The function that copies the accuracy parameters
The adjustment results of the main camera are reflected to the other cameras automatically, which
reduces the time to adjust the other cameras.