For Ser v ice E n gineer Service Information SI1610004E -000= YSM10_Proced ures for the adjustmen ts required after installing a machine 67/107  Default strage stor age position The storage position of the 󵪼󵮄 QFP is s…

100%1 / 107
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
66/107
4. Check the setting of “Mark”.
Select the mark number to be used when performing measurement after mounting the 󵪼󵮄 QFP.
Basically select “29”.
Select the jig to be used for the adjustment from the pull-down menu below the “Mark” item. The
coordinates of the marks at the four (4) corners of the 󵪼󵮄 QFP are automatically determined by
selecting the jig (󵪼󵮄 QFP).
5. Check the setting of “UtclXY” and “UtclR”.
Basically the setting is automatically done and the appropriate values are displayed. These values
are used for the automatic feedback.
When you lose track of the specified value,
default to change the settings back to
default.
[Specified upper limit value]
*Normally adjustment is NOT performed for the 303 (314) 󳬹󳴵.
󳬹󳴵
QFP
UtclXY
UtclR
󳬹󳴵304 (315)
68-pin 󵪼󵮄 QFP
0.035
0.15
󳬹󳴵307 (318)
208-pin 󵪼󵮄 QFP
0.035
0.15
󳬹󳴵303 (314)
16-pin 󵪼󵮄 QFP
0.035
1.00
Table 32
6. Check the Storage Pos. XY”.
Even when performing the adjustment with only one type of 󳬹󳴵, the position to temporarily
place the jig (󵪼󵮄 QFP) needs to be specified somewhere on the station. The position should be
somewhere that does not affect the mounting adjustment. Set the coordinates with reference to the
Block Offset value (Do not change the “Board Offset” and the Block Offset values). When
performing the adjustment for other 󳬹󳴵s, specify the “StoragePos” of the component to be
used for each 󳬹󳴵.
Figure 89
[Trace Storage]
to check the
coordinates of the storage
position.
If you [Default] ,
the Storage Pos.
coordinates are changed
back to the Storage Pos.
coordinates of the standard
FAMF station.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
67/107
Default strage storage position
The storage position of the 󵪼󵮄 QFP is set near the mounting position on the FAMF station as
default.
Set the 󵪼󵮄 QFP to be along with the end face of the
10mm holes near the center of the station.
It is the default storage position.
Figure 90
FAMF station
󵪼󵮄 QFP
Storage Pos X (mm)
Storage Pos Y (mm)
Standard (240X170mm)
68-pin
143.0
75.0
208-pin
69.0
75.0
16-pin
110.0
101.5
Small-sized
(100X100mm
68-pin
73.0
40.0
208-pin
8.0
40.0
16-pin
40.0
66.5
Table 33
Storage position for the FAMF station with the jig sticker
When using the FAMF station with the jig sticker for Calib Auto, it is possible to set the 󵪼󵮄 QFP
on the specified spot on the sticker to perform the adjustment.
Figure 91
[Storage Pos. XY]
FAMF station
󵪼󵮄 QFP
Storage Pos X (mm)
Storage Pos Y (mm)
Standard station
with the jig sticker
(240x170mm)
68-pin
62.5
34.5
208-pin
147.0
22.5
16-pin
107.0
18.0
Table 34
16-pin QFP
208-pin QFP
68-pin QFP
Set the 󵪼󵮄 QFP to be along
with the end face of the
10mm holes on the station.
Set the 󵪼󵮄 QFP to be
along with the end face of
the station.
Small FAMF station
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
68/107
7. Check the setting of “Mount No.”.
Specify the “Mount No.” in the board data (MCH_SETUP) to set the mounting position X, Y.
Only the XY coordinates are used for the Mount No.(The part numbers and the head numbers
are not used.) Select the Mount No. according to the FAMF station to be used.
Figure 92
FAMF station
Mount No.
Local Fiducial
Standard (240X170mm)
1
1
Small (100X100)
2
2
Table 35
8. Check the mounting position by tapping the [Trace]
.
When the
is tapped, the fiducial camera moves to the mounting coordinate set in the “Mount
No.” item. The is also used to move the camera to the mark position when recognizing the
marks on the four corners of the jig (󵪼󵮄 QFP), and checking if they can be recognized properly.
9.
[Rec. Test] to perform the recognition test for the QFP mark.
The recognition test for the marks on the four corners of the jig (󵪼󵮄 QFP) is performed.
If a recognition error occurs, select “No.29 󵪼󵮄QFP_0.5_Circle“ from the list on the
[Mark][Vision] window, and then perform the necessary adjustment on the “Mark Adj” window.
10. Check the setting of “Block No.”.
Specify which block offset number in the board data (MCH_SETUP) is to be used.
It is determined depends on the machine specification (the board flow direction, the location of the
fixed conveyor).
* Even though the “Skip” checkbox of the Block Offset (on the [Board]-[Offset] window) is ticked, it is
not effective.
Block
No.
Board data pattern name
Conveyor specification
1
Flow_R_Fixed_Front
Entrance of the conveyor: Right
Fixed conveyor: Front
2
Flow_L_Fixed_Front
Entrance of the conveyor: Left
Fixed conveyor: Front
3
Flow_R_Fixed_Rear
Entrance of the conveyor: Right
Fixed conveyor: Rear
4
Flow_L_Fixed_Rear
Entrance of the conveyor: Left
Fixed conveyor: Rear
Table 36
11. Check the setting of “With Fiducial Correction”.
Set whether to perform recognition of the block fiducial of the station or not. It is normally
performed.
This is the end of the preparation process for the mounting adjustment.
Caution:
Check the following before performing the adjustment.
The “Vacuum” function of all the heads is NOT activated.
The 󵪼󵮄 QFP is set to the storage position.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/