YSM10安装调整(eng).pdf - 第74页

For Service Engineer Service Information SI1610004E - 000 = YSM10_Procedures for the adjustments required a fter installing a machine 74 / 107  “Calc” tab The detailed inform ation of the mounting resu lt for each adjus…

100%1 / 107
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
73/107
6.9.2 Export the Result.dat accuracy data after the adjustment
If the status of the accuracy data after the adjustment needs to be graphed out on the VgChart,
export the Result.dat file and create VgChart by using the VgChart Utility on other PC.
1. Select the file to be exported.
Tick the checkboxes of the files to be exported on the Date column.
Figure 102
2. Select Write Result data from the File pull-down menu.
Figure 103
3. Specify the destination and save the data.
The data is written to the specified destination as the Result.dat file.
* The accuracy data before the adjustment can be exported on FeedbackLog.
See 6.9.5 Export the accuracy data Result.dat before the adjustment for the method.
6.9.3 Other tabs
The adjustment result can be checked on the “Data” tab, and the detailed result can be checked
on the following tabs.
Figure 104
“Index” tab
The detailed information of the Index for each adjustment result can be checked.
Figure 105
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
74/107
“Calc” tab
The detailed information of the mounting result for each adjustment can be checked.
Figure 106
“Precision”
The parameter calibration information for each adjustment result can be checked.
Figure 107
“Result” tab
The mounting result after the adjustment for each result can be checked on the graph.
Figure 108
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
75/107
6.9.4 “Feedback log confirmation window
If you select “Feedbacklog, you can check the record that the feedback has been performed during
the adjustment.
Figure 109
6.9.5 Export the accuracy data Result.dat before the adjustment
When printing out the accuracy data before the adjustment (before maintenance) on the VgChart,
export the Result.dat file from the Feedback Log” and create the graph on other PC.
The oldest data of the adjustment date in the Feedback Log” is the accuracy data for each 󳬹󳴵
and head before the adjustment.
1. Select the file to export.
Tick the Date checkbox of the file to be exported.
Figure 110
2. Export the file.
Select “Write Result data” from the File pull-down menu.
Figure 111
3. Select the destination to save the file.
The file is saved as the name Result.dat file in the specified destination.
6.9.6 Error Log confirmation window
If the adjustment cannot be completed properly, the log is saved. Mainly when the repeatability of
the mounting operation is poor, the adjustment is interrupted and the precision parameter, the
mounting result, Index and so on at the time of interruption is recorded. Identify the cause of the
problem, take appropriate measures and perform the adjustment again.