YSM10安装调整(eng).pdf - 第71页

For Ser v ice E n gineer Service Information SI1610004E -000= YSM10_Proced ures for the adjustmen ts required after installing a machine 71/107 6.9 Check the T otal Index In the “A CP - Station” adjustm ent, the result f…

100%1 / 107
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
70/107
3. Check if the measurement and the adjustment have been completed properly.
If any of the adjustments for the set item cannot be completed properly, an error message
appears.
Figure 96
Check the following to identify the cause of the problem and take appropriate measures, then
perform the adjustment again.
Items to be checked:
The FAMF station is secured properly, and the mounting surface is level (No deformation is
found on the station).
The 󵪼󵮄 QFP can be properly mounted on the station properly during the mounting process.
Check the “Parts” information: “Body Size Z” 1.0mm, “Mount Height” 0.2mm,
“Mount Timer sec” 0.3sec
The O-ring at the 󳬹󳴵 tip is not contaminated or deformed.
The leaf springs are properly set to the 󳬹󳴵 and the holding force is sufficient.
The marks on the FAMF station and on the 󵪼󵮄 QFP can be recognized properly.
:
The measurement results can be checked on the “Result” tab as well.
4. Make sure that the adjustment has been completed on the Result tab.
The measurement results can be checked on the “Result” tab.
The adjustment process is shown on the left-side pane, and it remains displayed even when the
adjustment process is interrupted halfway.
When the adjustment restarts, the process starts being displayed again from the point it was
interrupted.
The right-side pane shows the adjustment process by using the character string.
Figure 97
:
The result of the adjustment is saved in the automatically created folder (with the name of the data that
the adjustment is performed) in the following address.
Address: D¥Machine¥Result¥ACPResult¥
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
71/107
6.9 Check the Total Index
In the “ACP-Station” adjustment, the result files are saved separately per head.
6.9.1 FinishLog confirmation window
1. [Log] to open the log file.
When the [Log]
at the bottom of the window is tapped, the folder of the date when the [Log]
is tapped opens automatically. Select the “AutoFeedBackLog.xml” file and open it.
The log files are automatically created by the date of the adjustment.
Figure 98
2. Select FinishLog.
When the log window appears, select “FinishLog”.
Figure 99
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
72/107
3. Display the “Data” tab on the “FinishLog” window.
Index 1, 2 of the final data that have been adjusted separately can be checked on the window.
Figure 100
4. Check the total Index.
If you tick the checkboxes on the left of the chart, the worst value of the Index 1 and 2 are indicated
by the boldface.
The figure below shows the total Index of Digital 5.
Figure 101
5. Fill in the Total Index (Index1, Index 2) on the check sheet.