00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第131页
4 Electrics and control system 4.10 Replacing the I/O control unit Service Manual SIPLACE X-Serie S 06/2019 131 Fig.159: 03052315-02 LEDs [03052315-02] [03116049-01] LED Color Status Signal name Description H3 RD ON _RS…

4 Electrics and control system
4.10 Replacing the I/O control unit
130 Service Manual SIPLACE X-Serie S 06/2019
LEDs, Displays
Fig.158: 03052315-02
7-segment display H1 [03052315-02]
Display Status Description
Dot Flashes Circuit board OK
0 ON Firmware OK
1 ON CAN telegram cannot be transmitted
2 ON FW error: overflow in the CAN bus receiver buffer
3 ON CAN bus controller in the status ERROR PASSIVE
4 ON CAN bus controller in the status BUS OFF
5 ON Processor board received a message instead of a command
6 ON PowerFail signal active
F ON Other error
Any ON Hardware problem
A ON When initializing: BIOS mode changes to application mode
b ON When booting: head processor remains in BIOS mode

4 Electrics and control system
4.10 Replacing the I/O control unit
Service Manual SIPLACE X-Serie S 06/2019 131
Fig.159: 03052315-02
LEDs [03052315-02] [03116049-01]
LED Color Status Signal name Description
H3 RD ON _RSTOUT Signals a RESET
LEDs Outputs X8qb [03052315-02] [03116049-01]
LED Color Status Signal name Description
H48 GN Flashes DO15 No PCB in conveyor lane 2
H49 GN ON DO14 Failure on location 2
H2 GN ON DO13 Failure on location 1
H51 GN Flashes DO12 No PCB in conveyor lane 1
H44 GN ON DO11 Control speaker 2
H45 GN ON DO10 Control speaker 1
H46 GN - DO9 Not used
H47 ON - DO8 24V interlock hood 1 and 2 (option)
LEDs Outputs X7qb [03052315-02] [03116049-01]
LED Color Status Signal name Description
H40 GN - DO7 Not used
H41 GN ON DO6 Vacuum pump switched on (option)
H42 GN OFF DO5 Opens the main valve
H43 GN - DO4 Not used
H36 GN ON DO3 Switches the shut-off valve, COT insert
H37 GN - DO2 Not used
H38 GN ON DO1 Software_Ctrl On
Software ready, safety circuit closed
H39 GN - DO0 Not used

4 Electrics and control system
4.10 Replacing the I/O control unit
132 Service Manual SIPLACE X-Serie S 06/2019
LEDs Inputs X6qb [03052315-02] [03116049-01]
LED Color Status Signal name Description
H34 GN - DI 31 Not used
H35 GN - DI30 Not used
H32 GN - DI29 Not used
H33 GN - DI28 Not used
H30 GN - DI27 Not used
H31 GN - DI26 Not used
H28 GN - DI25 Not used
H29 GN - DI24 Not used
LEDs Inputs X5qb [03052315-02] [03116049-01]
LED Color Status Signal name Description
H26 GN - DI23 Not used
H27 GN - DI22 Not used
H24 GN - DI21 Not used
H25 GN ON DI20 EMERGENCY STOP button released on location 2
H22 GN - DI19 Not used
H23 GN ON DI18 CO trolley docked in on location 2
H20 GN ON DI17 Hood closed on location 2
H21 GN - DI16 Not used
LEDs Inputs X4qb [03052315-02] [03116049-01]
LED Color Status Signal name Description
H18 GN ON DI15 Operating pressure reached
H19 GN - DI14 Not used
H16 GN - DI13 Not used
H17 GN ON DI12 EMERGENCY STOP button released on location 1
H14 GN ON DI11 PowerEnable signal from power supply
H15 GN ON DI10 CO trolley docked in on location 1
H12 GN ON DI9 Hood closed on location 1
H13 GN ON DI8 EMERGENCY STOP button released on WPC
LEDs Inputs X3qb [03052315-02] [03116049-01]
LED Color Status Signal name Description
H10 GN ON DI7 Vacuum pump switched on
H11 GN DI6 Not used
H8 GN ON DI5 Stop button actuated
H9 GN ON DI4 Start button actuated
H6 GN ON DI3 Temperature monitoring, ballast resistor
H7 GN ON DI2 Vacuum pump OK
H4 GN ON DI1 Control_ON signal active
H5 GN ON DI0 Safety circuit closed