00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第94页

3 Power supply 3.5 Power supply and transformer module (from serial number Hxxxx) 94 Service Manual SIPLACE X-Serie S 06/2019 Fig.109: Cover – fastening screws ► Remove the six screws (2) fastening the cover (1) . Fig…

100%1 / 428
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
Service Manual SIPLACE X-Serie S 06/2019 93
3.5.6 Replacing the Contactor Safety Breaker [03112066-xx]
DANGER
High voltages
High DC voltages can be present in the contactor safety breaker.
No parts of the contactor safety breaker may be replaced.
Only the front cover of the contactor safety breaker may be dismantled for connecting
cables or removing the complete unit.
The contactor safety breaker may only be replaced as a complete unit.
Parts, equipment and tools
Fig.108: Contactor safety breaker [03112066‑xx]
Contactor safety breaker [03112066‑xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.5.4 "Checking For
Absence of Voltage" [}86].
Pull the power supply out of the machine.
3.3 "Pulling out the Power Supply" [}51]
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
94 Service Manual SIPLACE X-Serie S 06/2019
Fig.109: Cover – fastening screws
Remove the six screws(2) fastening
the cover(1).
Fig.110: Unplugging the electrical connections (example of
SIPLACE SX1/SX2 shown)
Unplug the electrical connections (1) to
(4). You might like to mark their posi-
tions to make clear assignment easier
later on.
Fig.111: Removing the contactor safety breaker (example of
SIPLACE SX1/SX2 shown)
Figure (B) shows the power supply; the con-
tactor safety breaker is removed for a better
view.
Loosen the screw(1) on the rear of the
contactor safety breaker.
To access the screw, route an exten-
sion past the side of the contactor
safety breaker.
Lift the contactor safety breaker up a
bit.
Unplug the electrical connections
between the contactor safety breaker
and the buffer module (2).
Lift the contactor safety breaker off.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Make sure that the cables are run correctly.
The cables must not be pinched or rub against unprotected edges.
Make sure that the cables are run out of the contactor safety breaker through the two re-
cessesprovided only.
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
Service Manual SIPLACE X-Serie S 06/2019 95
3.5.7 Replacing the AC/DC Converter
Parts, equipment and tools
Fig.112: Overview of the AC/DC converter
1.
PS1: AC-/DC converter DC300/150V
1.3kW 3 phase [03103087‑xx]
300/160 V for gantry 1/4
2.
PS2: AC-/DC converter DC300/150V
1.3kW 3 phase [03103087‑xx]
300/160 V for gantry 2/3
3.
PS3: AC/DC converter 36V 26.7A
960W 3 phase [03103331‑xx]
→ 42 V for Vision, head, conveyor mo-
tors
4.
PS4: AC/DC converter DC24V/40A 3
phase [03102840‑xx]
→ 27 V for FCU
5. AC/DC converter DC24V/20A 3
phase [03055232‑xx]
→ 24V
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.5.4 "Checking For
Absence of Voltage" [}86].
When replacing the AC/DC converter fitted at the side:
Pull the power supply out of the machine a little.
Unplug all electrical connections from the AC/DC converter. You may want to mark the posi-
tions of these connections to make clear assignment easier later on.
Open the lock under the AC/DC converter. Tilt the AC/DC converter slightly upwards and then
take it up and off.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Set the AC/DC converter (see 3.5.8 "Setting the Voltage on the AC/DC Convert-
ers" [}96]).