3 Power supply 3.5 Power supply and transformer module (from serial number Hxxxx) Service Manual SIPLACE X-Serie S 06/2019 93 3.5.6 Replacing the Contactor Safety Breaker [03112066-xx] DANGER High voltages High DC voltag…

100%1 / 428
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
92 Service Manual SIPLACE X-Serie S 06/2019
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.5.4 "Checking For
Absence of Voltage" [}86].
Slightly pull the power supply out of the machine.
WARNING
Carefully pull out the power supply
The power supply is not permanently fixed and can fall out of the machine.
Pull the power supply out of the machine but not too far.
If necessary, use suitable support e. g. a wooden beam.
Fig.107: Removing the buffer module
Unplug all electrical connections(1) for
the buffer module. If necessary, mark
their positions to make clear assign-
ment easier later on.
Undo the fastening screws(2).
Lift the buffer module off the rail.
Installation
Follow the removal instructions in reverse order for installation.
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
Service Manual SIPLACE X-Serie S 06/2019 93
3.5.6 Replacing the Contactor Safety Breaker [03112066-xx]
DANGER
High voltages
High DC voltages can be present in the contactor safety breaker.
No parts of the contactor safety breaker may be replaced.
Only the front cover of the contactor safety breaker may be dismantled for connecting
cables or removing the complete unit.
The contactor safety breaker may only be replaced as a complete unit.
Parts, equipment and tools
Fig.108: Contactor safety breaker [03112066‑xx]
Contactor safety breaker [03112066‑xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.5.4 "Checking For
Absence of Voltage" [}86].
Pull the power supply out of the machine.
3.3 "Pulling out the Power Supply" [}51]
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
94 Service Manual SIPLACE X-Serie S 06/2019
Fig.109: Cover – fastening screws
Remove the six screws(2) fastening
the cover(1).
Fig.110: Unplugging the electrical connections (example of
SIPLACE SX1/SX2 shown)
Unplug the electrical connections (1) to
(4). You might like to mark their posi-
tions to make clear assignment easier
later on.
Fig.111: Removing the contactor safety breaker (example of
SIPLACE SX1/SX2 shown)
Figure (B) shows the power supply; the con-
tactor safety breaker is removed for a better
view.
Loosen the screw(1) on the rear of the
contactor safety breaker.
To access the screw, route an exten-
sion past the side of the contactor
safety breaker.
Lift the contactor safety breaker up a
bit.
Unplug the electrical connections
between the contactor safety breaker
and the buffer module (2).
Lift the contactor safety breaker off.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Make sure that the cables are run correctly.
The cables must not be pinched or rub against unprotected edges.
Make sure that the cables are run out of the contactor safety breaker through the two re-
cessesprovided only.