3 Power supply 3.5 Power supply and transformer module (from serial number Hxxxx) Service Manual SIPLACE X-Serie S 06/2019 83 3.4.22 Replacing the machine mains power connection cable Parts, equipment and tools ● Machine…

100%1 / 428
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
82 Service Manual SIPLACE X-Serie S 06/2019
3.4.21.1 Adjustment of the Motor Protection Switch PKE32
This section applies only for the "motor protection switch PKE32" [03098183‑xx].
NOTICE
Supply of the vacuum pump with machine current
The following adjustment values are valid for all machines.
Exception: For machines with vacuum pumps that are supplied via the machine power sup-
ply other values may apply.
Fig.92: Adjusting the settings of the protective motor switch PKE32
1 Rated current 2 Overcurrent class
At the marked position (green arrow), open the cover above the adjustment screws. Use a
size 1 screwdriver for this.
Set the overcurrent class (2) to the value 5. This applies to all machines.
Set the rated current (1) to the following values:
Without vacuum pump
240/400V 50Hz network: rated current: 8.0A
110/208V 60Hz USA network: rated current: 13.5A
With one vacuum pump
(SX1/SX2, DX1/DX2, SX4/DX4,
X-Series S)
240/400V (50Hz) network: rated current: 8.0A
110/208V (60Hz ) USA network: rated current: 13.5A
With two vacuum pumps
(SX4/DX4, X-Series S)
240/400V (50Hz) network: rated current: 13.5A
110/208V (60Hz ) USA network: rated current: 17.2A
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
Service Manual SIPLACE X-Serie S 06/2019 83
3.4.22 Replacing the machine mains power connection cable
Parts, equipment and tools
Machine line connection cable [00335210-xx]
Removal/installation
Read the relevant chapter of the user manual.
3.5 Power supply and transformer module (from serial
number Hxxxx)
DANGER
Checking for absence of voltage!
Before you start working, check the power supply for absence of voltage and observe
the waiting times!
See also
2 3.5.4 "Checking For Absence of Voltage" [}86]
3.5.1 Overview
Fig.93: Overview of the power supply front
1. AC/DC converter DC24V/40A 3 phase
[03102840‑xx]
2. Circuit breaker FAZ-C16/3-NA 16A 3p
[03118366‑xx]
3. AC/DC converter DC300/150V 1.3kW 3
phase [03103087‑xx]
4. Main switch [03114066-xx]
5. AC-/DC converter 36V 26.7A 960W 3
phase [03103331‑xx]
6. Service socket (if present)
7. Measuring points for absence of voltage
2x 300 V DC and ground
8. AC/DC converter DC300/150V 1.3kW 3
phase [03103087‑xx]
9. Locking screw for power supply
Fig.94: Overview of the power supply at the side
1. Contactor safety breaker [03112066‑xx]
2. Distribution and fusing assembly X-
SeriesS [03118289‑xx]
3. Connections for vacuum pump
4. Connection for 110 Volt option
5. Capacitor battery PCS417.771
[03106016‑xx]
6. AC/DC-Converter DC24V/20A 3-
PHASE [03055232‑xx]
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
84 Service Manual SIPLACE X-Serie S 06/2019
3.5.2 Overview of Distributor and I/O Module
Fig.95: Distributor [03103753-02] (with SMPS)