00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第145页

6 Gantries 6.1 Gantries Service Manual SIPLACE X-Serie S 06/2019 145 6 Gantries DANGER Observe User Manual ► Please observe the safety instructions in the user manual for all work! CAUTION Use the correct blanking plugs …

100%1 / 428
5 Pneumatic System
5.10 Replacing the electronic ballast for the ELMO blower
144 Service Manual SIPLACE X-Serie S 06/2019
6 Gantries
6.1 Gantries
Service Manual SIPLACE X-Serie S 06/2019 145
6 Gantries
DANGER
Observe User Manual
► Please observe the safety instructions in the user manual for all work!
CAUTION
Use the correct blanking plugs
► Only use blanking plugs in the machine which match the manufacturer's compressed
air connection. A tight fit cannot be guaranteed for other blanking plugs.
► We recommend the use of blanking plugs made by Festo.
6.1 Gantries
Fig.179: Overview of gantry
1. Head interface and Vision board
The Vision board is fitted on the head
interface.
2. Y axis trailing cable
3. Y axis
4. X axis
5. X axis trailing cable
6. Y drive (primary)
7. Y scale
6.2 Replacing the Gantry
DANGER
Danger of crushing
The attraction force of the magnets is 400Nm.
CAUTION
Do not loosen or remove the screws
The loosening and removing of the fastening screws leads to tension. This has a negative
effect on the product life.
NOTICE
SIPLACE Service
This task may only be performed by SIPLACE service technicians.
6 Gantries
6.3 X and Y axis
146 Service Manual SIPLACE X-Serie S 06/2019
6.3 X and Y axis
6.3.1 Replacing the X axis incremental encoder
Parts, equipment and tools
●
Select the correct incremental encoder:
Machine Incremental encoder (read head)
SIPLACE X4i S, X4 S, X3 S, X2 S MS22/25 X axis [03094995‑xx]
SIPLACE X4i S micron, X4 S micron MS30 X axis [03102066‑xx]
●
For MS22/25 incremental encoder: test device PG1-I [03102699‑xx]
●
For MS20/30/35 incremental encoder: test device PG-U [03071361‑xx] from FS02 (see also
technical information "Checking the track signals at the X and Y axes" [DE:TI2019‑02D04]
[EN:TI2019‑02E04])
●
Sealing varnish Loctite 241 [02101037-xx]
●
Ethanol
Isopropanol – IPA can be used as an alternative.
●
Stepladder, if required
Overview
Fig.180: Overview
1. Vision board
2. Placement head on gantry
3. Head interface
4. Cable from temperature sensor and in-
cremental encoder X axis to head inter-
face
5. The X axis incremental encoder
6. Temperature sensor