2 Basic Machine 2.8 Nozzle Changers and Reject Boxes 46 Service Manual SIPLACE X-Serie S 06/2019 2.8.3 Setting the Nozzle Reject and Station Height Parts, equipment and tools ● Depth measuring gauge (300mm) [03079617-xx…

2 Basic Machine
2.8 Nozzle Changers and Reject Boxes
Service Manual SIPLACE X-Serie S 06/2019 45
Fig.39: Overview of nozzle changers
1. Cover (covering complete electronic
and pneumatic systems)
2. Compressed air connection
3. Four fastening screws
4. Valve
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
► Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}134]
► Remove all magazines.
► Remove the four fastening screws.
► Unplug the nozzles changer from all electrical and pneumatic connections. You might like to
mark their positions to make clear assignment easier later on.
► Take care not to lose the support plates. Remember their exact positions, as they will need to
be returned to these original positions, during assembly.
► Carefully lift the nozzle changer out of the machine.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
●
If present: Check the switch on the nozzle changer (see 2.8.5 "Jumpers on the Nozzle
Changer" [}48]).
●
Re-insert the support plates. Check the mechanical installation height of the nozzle changer
(see 2.8.4 "Setting the Nozzle Changer Height" [}47]).

2 Basic Machine
2.8 Nozzle Changers and Reject Boxes
46 Service Manual SIPLACE X-Serie S 06/2019
2.8.3 Setting the Nozzle Reject and Station Height
Parts, equipment and tools
●
Depth measuring gauge (300mm) [03079617-xx]
●
Shim plates for nozzle reject device [03039514-xx]
●
Screws DIN 7991-M4 x 20-8.8 [00333782-xx]
●
Plastic sheet (to keep the depth measuring gauge away from the magnets)
Setting
Fig.40: Measurement
1. Position upper edge of measuring scale
on the linear guidance
2. Bottom end of measuring gauge on the
assembly surface of the nozzle station
► Push the placement head to be meas-
ured outwards.
► Place a plastic plate in front of the mag-
nets.
► Position the measuring gauge on the
upper edge of the nozzle station
assembly surface and measure the dis-
tance to the upper edge of the lower X
axis linear guidance.
CAUTION!
Hold the measuring scale vertically!
.
Fig.41: Shim plates
1. Shim plates
2. Slot
► Set a distance of 139.0±0.2mm for all
placement heads.
If the distance is too large, insert shim
plates:
shim plates for nozzle stripping
device[03039514‑xx],
screws DIN7991 M4x20 - 8.8
[00333782‑xx]

2 Basic Machine
2.8 Nozzle Changers and Reject Boxes
Service Manual SIPLACE X-Serie S 06/2019 47
2.8.4 Setting the Nozzle Changer Height
Parts, equipment and tools
●
Measuring scale
●
NC shim plate [03021079-xx]
Overview
5
1
4
3
2
Fig.42: Overview of measurement procedure
1. Measuring scale
2. Top edge of the X axis lower linear
guide
3. Values to be set (150 +/- 0.2 mm)
4. Nozzle changer contact surface
Setting
► During the following inside measurement make sure that the tip of the measuring scale does
not touch the magnetic strip as this might scratch it!
CAUTION
Strong magnetic forces
Place a suitable plastic plate between the magnet and measuring scale.
► Position the measuring scale (1) on the top edge of the X axis lower linear guide (2) and
measure the distance to the nozzle changer contact surface (4).
► Hold the measuring scale vertically (1).
► The setting value (4) is 150+/‑0.2mm
.You can adjust the height, where necessary, by removing or adding NC shim plates.
CAUTION
Crash hazard!
Do not place too many shim plates underneath.
► Repeat this measurement on the inside of the gantry (5).
► Calibrate the position of the nozzle changer.