00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第66页

3 Power supply 3.4 Power supply and transformer module (up to serial number Gxxx) 66 Service Manual SIPLACE X-Serie S 06/2019 3.4.13 Replacing the output coupling link (K7) Parts, equipment and tools Fig.66: Output coup…

100%1 / 428
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
Service Manual SIPLACE X-Serie S 06/2019 65
3.4.12 Replacing the protective contactor combination
Parts, equipment and tools
Fig.65: Protective contactor combination
1. Protective contactor combination
3TK28 25 [00358268-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Before you start working, check the power supply for absence of voltage and observe the
waiting times!
Unplug all connections to the protective contactor combination. You might like to mark their
positions to make clear assignment easier later on.
Take the protective contactor combination off the rail. To do this, press the protective con-
tactor combination upwards slightly and tilt it.
Installation
Follow the removal instructions in reverse order for installation.
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
66 Service Manual SIPLACE X-Serie S 06/2019
3.4.13 Replacing the output coupling link (K7)
Parts, equipment and tools
Fig.66: Output coupling link
1. Output coupling link 24V AC/DC 1W
[03065954-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Before you start working, check the power supply for absence of voltage and observe the
waiting times!
Unplug all connections to the output coupling link. You might like to mark their positions to
make clear assignment easier later on.
Take the output coupling link off the rail.
Installation
Follow the removal instructions in reverse order for installation.
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
Service Manual SIPLACE X-Serie S 06/2019 67
3.4.14 Replacing the socket
Parts, equipment and tools
Fig.67: Socket
1. Socket, rail-mounted SD-D/SC/LA/GY
[00375320‑xx]
 NOTICE!
The socket might be not be fitted in
some machine versions.
.
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Before you start working, check the power supply for absence of voltage and observe the
waiting times!
Unplug all connections to the socket. You might like to mark their positions to make clear as-
signment easier later on.
Take the socket off the rail.
Installation
Follow the removal instructions in reverse order for installation.