00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第197页

6 Gantries 6.6 HCU, MHCU, boards and camera Service Manual SIPLACE X-Serie S 06/2019 197 Overview Fig.248: Overview of PCB camera 1. Gantry 2. PCB camera The PCB camera is located on the under- side of the gantry, on th…

100%1 / 428
6 Gantries
6.6 HCU, MHCU, boards and camera
196 Service Manual SIPLACE X-Serie S 06/2019
6.6.4 Replacing the connection cable from the Twin module to the HCU basic
adapter
Parts, equipment and tools
●
Cable / X connection cable Twin [03062202-xx]
Overview
Fig.247: Cables
1. Connection cable from the Twin mod-
ule to the HCU basic adapter
2. Twin module
3. HCUs on the HCU base adapter
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory work..." [}16].
► Remove the two Twin modules form the machine (see 8.7 "Replacing the SIPLACE
Twin" [}320]).
► Remove the head adapter HCU from the machine and then dismantle the two HCUs. (see
6.6.1 "Replacing the MHCU, basic and head adapter" [}191]).
► Unplug both connection cables.
Installation
► Follow the removal instructions in reverse order for installation.
6.6.5 Replacing the PCB Camera
Parts, equipment and tools
●
SIPLACE X-Series S up to Gxxxx: PCB camera (type 34) 28 digital RK [03075363‑xx]
●
SIPLACE X-Series S from Hxxxx: PCB camera (type 34) 28 GigE [03101402‑xx]
●
Sealing varnish Loctite 241 [02101037-xx]
6 Gantries
6.6 HCU, MHCU, boards and camera
Service Manual SIPLACE X-Serie S 06/2019 197
Overview
Fig.248: Overview of PCB camera
1. Gantry
2. PCB camera
The PCB camera is located on the under-
side of the gantry, on the head mount.
Removal
Fig.249: Connecting cable
► Unplug the two connection cables X2
and X6(1) from the Vision board and
unthread as far as the PCB camera.
You may like to mark their positions, to
make clear assignment easier later on.
Fig.250: PCB camera
► Remove the four screws (1) holding the
PCB camera. Mark the position to
make clear assignment easier later on.
Installation
► Install the new PCB camera on the mount. Secure the screws with Loctite 241.
► Run the connection cable to the Vision board and reconnect to the electrical system.
► After replacing the PCB camera, you will need to recalibrate the whole machine. Use the rel-
evant software function in the Service menu.
6 Gantries
6.7 Filter and pneumatics
198 Service Manual SIPLACE X-Serie S 06/2019
6.7 Filter and pneumatics
6.7.1 Replacing the vacuum distributor on the placement head
Parts, equipment and tools
●
Distributor placement head vacuum [03029190-xx]
CAUTION
Use the correct blanking plugs
► Only use blanking plugs in the machine which match the manufacturer's compressed
air connection. A tight fit cannot be guaranteed for other blanking plugs.
► We recommend the use of blanking plugs made by Festo.
Overview
Fig.251: Overview of vacuum distributor
1. Vacuum distributor
 NOTICE!
There may still be a pressure sensor
on the vacuum distributor.
.
See 6.7.2 "Replacing the pressure
sensor" [}199].
Fig.252: Screws fastening the vacuum distributor
1. Screws fastening the vacuum distrib-
utor
The screws fastening the vacuum distributor
are located under the head interface.
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
► Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}134]
► Dismantle the Vision board spread spectrum (see 6.4.7 "Replacing the Vision board spread
spectrum HCU" [}178]).
► Dismantle the head interface (see 6.4.5 "Replacing the Head Interface" [}172]).