00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第39页
2 Basic Machine 2.7 Replacing Stationary Component Camera Digital Type 25/33/36 Service Manual SIPLACE X-Serie S 06/2019 39 2.7.2 Troubleshooting Stationary Cameras Error / problem ● Errors arise during nozzle scanning, …

2 Basic Machine
2.7 Replacing Stationary Component Camera Digital Type 25/33/36
38 Service Manual SIPLACE X-Serie S 06/2019
2.7.1 Installation Height of the Stationary Camera
CAUTION
Head crash danger
An incorrect installation height can result in a head crash!
The installation height at which the camera can be installed depends on the camera version. You
will either only be able to use one specific height or will have the option of several installation
heights. The following description only applies for the following camera versions with three possible
installation heights:
●
Stationary component camera P&P (type 33) 55x45 digit. [03016339-xx] from version -06
●
Stationary component camera P&P (type 36) 32x32 digit. [03042491-xx] from version -04
Stationary camera in position 1
Fig.27: Stationary camera in position 1
1. Screw
2. Thread in the machine frame
Position 1 has to be used in the following
cases:
●
SX1/SX2: always
●
SX4, X-Series: If at least one DLM or
CPP head is used in the corresponding
placement area.
Stationary camera in position 2
Position 2 is not relevant for the SX and the X-Series.
Stationary camera in position 3
Fig.28: Stationary camera in position 3
1. Screw
2. Thread in the machine frame
Position 3 has to be used in the following
cases:
●
SX1/SX2: never.
●
SX4, X-Series: If only TwinHeads are
used in the corresponding placement
area.

2 Basic Machine
2.7 Replacing Stationary Component Camera Digital Type 25/33/36
Service Manual SIPLACE X-Serie S 06/2019 39
2.7.2 Troubleshooting Stationary Cameras
Error / problem
●
Errors arise during nozzle scanning, even though the nozzle has already been checked to en-
sure that it is clean.
●
During camera verification (FCCS), it is difficult to achieve the necessary illumination.
●
Increased component rejection rate, particularly with low-contrast components.
Cause
If one or more of these errors occurs, the cause may be a dirty camera.
Solution
► Clean the stationary cameras. Please read the technical information [DE: TI2014-10D09] [EN:
TI2014-10E09] for more information.
Problem
●
Error message 37752: "The LED test of the camera illumination failed" at GigE cameras
Solution
► Please contact the SIPLACE service team for more information.
Give them the following reference number: TI2015-08V03.

2 Basic Machine
2.7 Replacing Stationary Component Camera Digital Type 25/33/36
40 Service Manual SIPLACE X-Serie S 06/2019
2.7.3 PCBs Stationary Cameras
2.7.3.1 Vision LED driver VLT 33
This board is part of the stationary cameras SST25, SST33 and SST36 (without GigE). The station-
ary cameras which can be installed will depend on the machine type.
Fig.29: 03039244-03
DIP switch S1 for SST25 [03039244-03]
Switch Status Signal name Description
S1.1 OFF VCU_CODE OFF: normal operation, ON: Reset
Location 1 Location 2 Location 3 Location 4
S1.2 ON/OFF GANTRY_ID_0 *) OFF ON OFF ON
S1.3 ON/OFF GANTRY_ID_1 *) OFF OFF ON ON
S1.4 OFF SMD_LED OFF: standard LED, ON: SMD LED
S1.5 OFF CAN_H OFF: with CAN terminator
ON: without CAN terminator
S1.6 OFF CAN_GROUP OFF: FC camera, ON: IC camera
*) Set the location at which the stationary camera is fitted.
DIP switch S1 for SST33, 36 [03039244-03]
Switch Status Signal name Description
S1.1 OFF VCU_CODE OFF: normal operation, ON: Reset
Location 1 Location 2 Location 3 Location 4
S1.2 ON/OFF GANTRY_ID_0 *) OFF ON OFF ON
S1.3 ON/OFF GANTRY_ID_1 *) OFF OFF ON ON
S1.4 OFF SMD_LED OFF: standard LED, ON: SMD LED
S1.5 OFF CAN_H OFF: with CAN terminator
ON: without CAN terminator
S1.6 ON CAN_GROUP ON: IC camera , OFF: FC camera
*) Set the location at which the stationary camera is fitted.
2.7.3.2 Vision LED Controller VLC25/33 GigE DTC
●
Vision LED Controller VLC33 GigE DTC [03117981-xx]
●
Vision LED Controller VLC25 GigE DTC [03117587-xx]
These two circuit boards are in principle identical. The VLC25 board however, also has the con-
nectors X21 and X22
The circuit boards are part of the stationary camera SST25/33 GigE.