Samsung Component Placer CP-45F(V)/FS Operations Manual B-14 … 'START': star ts operation with a PCB. … 'CONTINUE': continues at the point where the operation sto pped. Step11 - Press the START button…

100%1 / 76
Appendix B 3D Trouble Shooting Guide
B-13
3. Turn off all the LEDs by using the AXIS button.
4. Press the HOME START button.
- Then click on the NEXT button.
Step3 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
… 'CONTINUE': continues at the point where the operation stopped.
Step4 - Press the START button to resume operation
Error Code $0021 Link
Step Message
E - The rear door is open.
Step1 1. Close the rear door completely once more.
2. Press the STOP button. (Stop the buzzer sound).
3. Press the RESET button.
4. Press the READY button.
- Then click on the NEXT button.
Step2 1. Turn on the power for MOTOR.
2. Select the HOME mode by using the MODE button in the teaching box.
3. Turn off all the LEDs by using the AXIS button.
4. Press the HOME START button.
- Then click on the NEXT button.
Step3 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
… 'CONTINUE': continues operation at the point where the operation
stopped.
Step4 - Press the START button to resume operation.
Error Code $1000X Link
Step Message
E
- (-) H/W Limit is sensed at the X axis.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check if the X axis is out of the (-) H/W Limit.
. Yes, the X axis is out of the (-) H/W Limit. Step4
. No, the X axis is not out of the (-) H/W Limit. Step12
- Then click on the NEXT button.
Step4 - Open the equipment door.
Step5 - Manually move the X axis to a position in the H/W Limit
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 - Check the related setting from MMI.
Step8 1. Press the RESET button.
2. Turn on the power for MOTOR.
3. Press the READY button.
- Then click on the NEXT button.
Step9 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step10 - Click on START or CONTINUE on MMI.
Samsung Component Placer CP-45F(V)/FS Operations Manual
B-14
'START': starts operation with a PCB.
… 'CONTINUE': continues at the point where the operation stopped.
Step11 - Press the START button to resume operation.
Step12 -Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Error Code $1000Y Link
Step Message
E - (-) H/W Limit is sensed at the Y axis.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 -Open the equipment door.
Step3 - Check if the Y axis is out of the (-) H/W Limit.
. Yes, the Y axis is out of the (-) H/W Limit. Step4
. No, the Y axis is not out of the (-) H/W Limit. Step12
- Then click on the NEXT button.
Step4 - Open the equipment door.
Step5 - Manually move the Y axis to a position in the H/W Limit.
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 - Check the related setting from MMI.
Step8 1. Press the RESET button.
2. Turn on the power for MOTOR.
3. Press the READY button.
- Then click on the NEXT button.
Step9 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step10 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
… 'CONTINUE': continues at the point where the operation stopped.
Step11 - Press the START button to resume operation.
Step12 -Resume operation after checking the following.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Error Code $1001X Link
Step Message
E - (+) H/W Limit is sensed at the X axis.
Step1 - Press the STOP button. (Stop the buzzer sound )
Step2 - Open the equipment door.
Step3 - Check if the X axis is out of the (+) H/W Limit.
. Yes, the X axis is out of the (+) H/W Limit. Step4
. No, the X axis is not out of the (+) H/W Limit. Step12
- Then click on the NEXT button.
Appendix B 3D Trouble Shooting Guide
B-15
Step4 - Open the equipment door.
Step5 - Manually move the X axis to a position in the H/W Limit
- Then click on the NEXT button.
Step6 - Close the equipment door
Step7 - Check the related setting from MMI.
Step8 1. Press the RESET button
2. Turn on the power for MOTOR
3. Press the READY button
- Then click on the NEXT button
Step9 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step10 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
… 'CONTINUE': continues at the point where the operation stopped.
Step11 - Press the START button to resume operation.
Step12 - Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Error Code $1001Y Link
Step Message
E - (+) H/W Limit is sensed at the Y axis.
Step1 -Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check if the Yaxis is out of the (+) H/W Limit
. Yes, the Y axis is out of the (+) H/W Limit. Step4
. No, the Yaxis is not out of the (+) H/W Limit. Step12
- Then click on the NEXT button.
Step4 - Open the equipment door.
Step5 - Manually move the Y axis to a position in the H/W Limit.
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 - Check the related setting from MMI.
Step8 1. Press the RESET button.
2. Turn on the power for MOTOR.
3. Press the READY button.
- Then click on the NEXT button.
Step9 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step10 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
… 'CONTINUE': continues at the point where the operation stopped.
Step11 - Press the START button to resume operation.
Step12 -Check the following and resume operation.