B-15
Step4 - Open the equipment door.
Step5 - Manually move the X axis to a position in the H/W Limit
- Then click on the NEXT button.
Step6 - Close the equipment door
Step7 - Check the related setting from MMI.
Step8 1. Press the RESET button
2. Turn on the power for MOTOR
3. Press the READY button
- Then click on the NEXT button
Step9 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step10 - Click on START or CONTINUE on MMI.
… 'START': starts operation with a new PCB.
… 'CONTINUE': continues at the point where the operation stopped.
Step11 - Press the START button to resume operation.
Step12 - Check the following and resume operation.
… Check if there is any contaminant, such as grease, on the sensor.
… Check if the sensor or power supply area is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Error Code $1001Y Link
Step Message
E - (+) H/W Limit is sensed at the Y axis.
Step1 -Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check if the Yaxis is out of the (+) H/W Limit
. Yes, the Y axis is out of the (+) H/W Limit. Step4
. No, the Yaxis is not out of the (+) H/W Limit. Step12
- Then click on the NEXT button.
Step4 - Open the equipment door.
Step5 - Manually move the Y axis to a position in the H/W Limit.
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 - Check the related setting from MMI.
Step8 1. Press the RESET button.
2. Turn on the power for MOTOR.
3. Press the READY button.
- Then click on the NEXT button.
Step9 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step10 - Click on START or CONTINUE on MMI.
… 'START': starts operation with a new PCB.
… 'CONTINUE': continues at the point where the operation stopped.
Step11 - Press the START button to resume operation.
Step12 -Check the following and resume operation.

Samsung Component Placer CP-45F(V)/FS Operations Manual
B-16
… Check if there is any contaminant, such as grease, on the sensor.
… Check if the sensor or power supply area is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S).
Error Code $1002X Link
Step Message
E - The ALARM is sensed at the X axis.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check the following and click on the NEXT button.
… Check if there is any contaminant on the paths of the Gantry and the
Head.
… Check if the Motor is overloaded.
… Check if power supply is not normal, such as uneven voltage.
… In the case of Z axis, check the Z value.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Step4 - Close the equipment door.
Step5 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step6 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step7 - Click on START or CONTINUE on MMI.
… 'START': starts operation with a new PCB.
Step8 - Click on START or CONTINUE on MMI.
Step9 - Press the START button to resume operation.
Error Code $1002Y Link
Step Message
E - The ALARM is sensed at the Y axis.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check the following and click on the NEXT button.
… Check if there is any contaminant on the paths of the Gantry and the
Head.
… Check if the Motor is overloaded.
… Check if power supply is not normal, such as uneven voltage.
… In the case of Z axis, check the Z value.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Step4 - Close the equipment door.
Step5 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.

Appendix B 3D Trouble Shooting Guide
B-17
Step6 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step7 - Click on START or CONTINUE on MMI.
… 'START': starts operation with a new PCB.
Step8 - Click on START or CONTINUE on MMI.
Step9 - Press the START button to resume operation.
Error Code $1002Z Link
Step Message
E - The ALARM is sensed at the Z axis.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check the following and click on the NEXT button.
… Check if there is any contaminant on the paths of the Gantry and the
Head.
… Check if the Motor is overloaded.
… Check if power supply is not normal, such as uneven voltage.
… In the case of Z axis, check the Z value.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Step4 - Close the equipment door.
Step5 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step6 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step7 - Click on START or CONTINUE on MMI.
… 'START': starts operation with a new PCB.
Step8 - Click on START or CONTINUE on MMI.
Step9 - Press the START button to resume operation.
Error Code $2301 Link
Step Message
E - Can't move forward the Edge Fix.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check the operation of related sensor from the I/O Status of Diagnosis.
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then click on the NEXT button.
Step5 - Adjust the air pressure to the recommended value by using the air