APPENDIX.pdf - 第41页

Appendix B 3D T r ouble Shooting Guide B-19 Step7 1. Press the RESET button. 2. Turn on the power for MOTOR. 2. Press the READY button. - Then click on the NEXT button. Step8 1. Select the HOME mode by using the MODE but…

100%1 / 76
Samsung Component Placer CP-45F(V)/FS Operations Manual
B-18
pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned. Step12
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Error Code $2302 Link
Step Message
E - Can't move backward the Edge Fix.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check the operation of related sensor from the I/O Status of Diagnosis.
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then click on the NEXT button.
Step5
- Adjust the air pressure to the recommended value by using the air
pressure control valve.
- Was air pressure adjustment successful?
. Yes, air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control value was turned. Step12
- Then, click on the NEXT button.
Step6 - Close the equipment door.
Appendix B 3D Trouble Shooting Guide
B-19
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting area of the air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
Check if there is contaminant, such as grease, on the sensor.
Check if the sensor or power supply area of the sensor is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Error Code $3301 Link
Step Message
E - Can't raise the Wait Stopper.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3
- Check the operation of the related sensor from the I/O Status of
Diagnosis.
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then, click on the NEXT button.
Step5 - Adjust the air pressure by using the air pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned.
Step12
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
Samsung Component Placer CP-45F(V)/FS Operations Manual
B-20
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of the air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area of the sensor is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S.)
Error Code $3302 Link
Step Message
E - Can't lower the Wait Stopper.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check the operation of related sensor from the I/O Status of Diagnosis.
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then click on the NEXT button.
Step5
- Adjust the air pressure to the recommended value by using the air
pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned.
Step12
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of the air pressure hose and resume
operation.