Samsung Component Placer CP-45F(V)/FS Operations Manual B-24 Step5 - Adjust the air pressure to the re commended value by using the air pressure control valve. - Was air pressure adjustment successful? . Yes, the air pre…

100%1 / 76
Appendix B 3D Trouble Shooting Guide
B-23
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then click on the NEXT button.
Step5
- Adjust the air pressure to the recommended value by using the air
pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned. Step12
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of the air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area of the sensor is normal.
(If the problem persists even after above steps have been taken, please
contact our C/S.)
Error Code $3502 Link
Step Message
E - Can't lower the Out Stopper.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check if the related sensor operates from the I/O Status of Diagnosis.
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then click on the NEXT button.
Samsung Component Placer CP-45F(V)/FS Operations Manual
B-24
Step5
- Adjust the air pressure to the recommended value by using the air
pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned. Step12
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of the air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area of the sensor is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S)
Error Code $6002 Link
Step Message
E - Can't open the ANC.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door..
Step3 - Check if the related sensor operates from the I/O Status of Diagnosis.
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then click on the NEXT button.
Step5
- Adjust the air pressure to the recommended value by using the air
pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned.
Step12
- Then click on the NEXT button.
Appendix B 3D Trouble Shooting Guide
B-25
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of the air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area of the sensor is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S)
Error Code $6003 Link
Step Message
E - Can't close the ANC.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door..
Step3 - Check if the related sensor operates from the I/O Status of Diagnosis.
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then click on the NEXT button.
Step5
- Adjust the air pressure to the recommended value by using the air
pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned.
Step12
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.