Appendix B 3D T r ouble Shooting Guide B-27 Step Message E - The left sensor of Hole Fix is not sensed. Step1 - Press the STOP button. (Stop the buzzer sound). Step2 - Open the equipment door. Step3 - Check the size, pos…

Samsung Component Placer CP-45F(V)/FS Operations Manual
B-26
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
… 'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of the air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
… Check if there is any contaminant, such as grease, on the sensor.
… Check if the sensor or power supply area of the sensor is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S)
Error Code $2211 Link
Step Message
E - The right sensor of the Hole Fix is not sensed.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door..
Step3 - Check the size, position, and direction of the PCB.
Is the Hole Fixer inserted properly in the right Fix Hole?
. Yes, the Hole Fixer is inserted properly. Step4
. No, the Hole Fixer is not inserted properly. Step11
- Then click on the NEXT button.
Step4 - Adjust the position of the Sensor Dog.
- Then click on the NEXT button.
Step5 - Close the equipment door.
Step6 1. Press the RESET button.
2. Turn on the power for MOTOR.
3. Press the READY button.
- Then click on the NEXT button.
Step7 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
-Then click on the NEXT button.
Step8 - Click START or CONTINUE on MMI.
… 'START': starts operation with a new PCB.
Step9 - Click on START or CONTINUE on MMI.
Step10 - Press the START button to resume operation.
Step11 - Click on the BTU Down button in View->Manual Control of MMI.
- Then click on the NEXT button.
Step6 1. Remove the PCB after lowering the Backup Table.
2. Cancel the Hole Fixer.
3. Put the PCB.
4. Fit the Hole Fixer into the Fix Hole and secure it.
- Then click on the NEXT button. Step5
Error Code $2212 Link

Appendix B 3D Trouble Shooting Guide
B-27
Step Message
E - The left sensor of Hole Fix is not sensed.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door.
Step3 - Check the size, position, and direction of the PCB.
Is the Hole Fixer inserted properly in the left Fix Hole?
. Yes, the Hole Fixer is inserted properly. Step4
. No, the Hole Fixer is not inserted properly. Step11
- Then click on the NEXT button.
Step4 - Adjust the position of the Sensor Dog.
- Then click on the NEXT button.
Step5 - Close the equipment door.
Step6 1. Press the RESET button.
2. Turn on the power for MOTOR.
3. Press the READY button.
- Then click on the NEXT button.
Step7 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
-Then click on the NEXT button.
Step8 - Click on START or CONTINUE on MMI.
… 'START': starts operation with a new PCB.
Step9 - Click on START or CONTINUE on MMI.
Step10 - Press the START button to resume operation.
Step11 - Click on the BTU Down button in View->Manual Control of MMI.
- Then click on the NEXT button.
Step6 1. Remove the PCB after lowering the Backup Table.
2. Cancel the Hole Fixer.
3. Put the PCB.
4. Fit the Hole Fixer into the Fix Hole and secure it.
- Then click on the NEXT button. Step5
Error Code $3001 Link
Step Message
E - A PCB is in the input sensor area.
- Press START to continue operation.
- Click on Exit to end the TSG.
Error Code $3002 Link
Step Message
E - A PCB is in the waiting sensor area.
- Press START to continue operation.
- Click on Exit to end the TSG.
Error Code $3003 Link
Step Message
E - A PCB is in the mounting sensor area.
- Press START to continue operation.
- Click on Exit to end the TSG.

Samsung Component Placer CP-45F(V)/FS Operations Manual
B-28
Error Code $3004 Link
Step Message
E - A PCB is in the output sensor area.
- Press START to continue operation.
- Click on Exit to end the TSG.
Error Code $4300X Link
Step Message
E The X axis is sensed in the (-) S/W Limit by using the jog box.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Move the X axis to a position in the S/W Limit by using the teaching box.
- Then click on the NEXT button.
Step3 - Check the setting from the Limits item in the System menu of MMI.
Stpe4 - Press the START button to resume operation.
Error Code $4300Y Link
Step Message
E The Y axis is sensed in the (-) S/W Limit by using the Jog Box.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Move the Y axis to a position in the S/W Limit by using the teaching box.
- Then click on the NEXT button.
Step3 - Check the setting from the Limits item in the System menu of MMI.
Stpe4 - Press the START button to resume operation.
Error Code $4300Z Link
Step Message
E The Z axis is sensed in the (-) S/W Limit by using the Jog Box.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Move the Z axis to a position in the S/W Limit by using the teaching box.
- Then click on the NEXT button.
Step3 - Check the setting from the Limits item in the System menu of MMI.
Stpe4 - Press the START button to resume operation.
Error Code $4301X Link
Step Message
E The X axis is sensed in the (+) S/W Limit by using the Jog box.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Move the X axis to a position in the S/W Limit by using the teaching box.
- Then click on the NEXT button.
Step3 - Check the setting from the Limits item in the System menu of MMI.
Stpe4 - Press the START button to resume operation.
Error Code $4301Y Link
Step Message
E The Y axis is sensed in the (+) S/W Limit by using the Jog Box.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Move the Y axis to a position in the S/W Limit by using the teaching box.
- Then click on the NEXT button.
Step3 - Check the setting from the Limits item in the System menu of MMI.