APPENDIX.pdf - 第59页

Appendix C Shuttle T ray Feeder C-1 Appendix C. Shuttle T ray Feeder C.1. Registering Shuttle T r ay Feeder Figur e C-1. "T ray Feeder Sett ing" Dialog box After the Shuttle T ray Feeder has been i nstalled, re…

100%1 / 76
Samsung Component Placer CP-45F(V)/FS Operations Manual
B-36
Error Code $6009 Link
Step Message
E - No wanted nozzle in the ANC.
- Check and compare the setting and current array of the nozzle in the
ANC.
Step1 - Please contact Our C/S.
Error Code $600a Link
Step Message
E - XY Gantry couldn't move to the nozzle PICK position.
Step1 - Please contact Our C/S.
Error Code $a100 Link
Step Message
E - Error occurred while the Vision fiducial mark was processed.
Step1 - Specify the Fiducial Mark again and resume operation.
Appendix C Shuttle Tray Feeder
C-1
Appendix C. Shuttle Tray Feeder
C.1. Registering Shuttle Tray Feeder
Figure C-1. "Tray Feeder Setting" Dialog box
After the Shuttle Tray Feeder has been installed, register it from the Tray Feeder Setting
dialog box (Sys. SetupTray) in Figure C-1 as follows.
Enter the Tray Feeder name to specify in the Name item.
Select ‘FW-20CS (Shuttle) (393221)’ from the Type item.
Enter the origin of Tray Feeder using the method same as that for setting the existing
Tray Feeder.
Set the Channel and Comm ID for the communication between the CP45 equipment
and the Tray Feeder.
Enter the PAD position of the Shuttle that is waiting for the component supply in the
CP45 equipment.
As the Shuttle Tray Feeder does not occupy a separate Feeder Lane unlike the existing
Tray Feeder, the default value is automatically set to Not Usable Lane.
C.2. Testing Shuttle Tray Feeder Operation
After the Shuttle Tray Feeder has been registered, the user can check whether it operates
normally from the "Tray Feeder Communication Diagnosis" dialog box
Samsung Component Placer CP-45F(V)/FS Operations Manual
C-2
(DiagnosisTray) in Figure C-2.
Figure C-2. "Tray Feeder Communication Diagnosis " dialog box
The following operations can be checked in relation to Shuttle Tray Feeder.
S-Tray Pad Vacuum Off: Provides or stops air pressure to each PAD of the Shuttle.
S-Tray Shuttle Move: Moves the Shuttle to the CP45 equipment or the Tray Feeder.
S-Tray Head Z-Move: Operates the head of the Tray Feeder.