APPENDIX.pdf - 第47页

Appendix B 3D T r ouble Shooting Guide B-25 Step6 - Close the equipment door. Step7 1. Press the RESET button. 2. Turn on the power for MOTOR. 2. Press the READY button. - Then click on the NEXT button. Step8 1. Select t…

100%1 / 76
Samsung Component Placer CP-45F(V)/FS Operations Manual
B-24
Step5
- Adjust the air pressure to the recommended value by using the air
pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned. Step12
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of the air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area of the sensor is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S)
Error Code $6002 Link
Step Message
E - Can't open the ANC.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door..
Step3 - Check if the related sensor operates from the I/O Status of Diagnosis.
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then click on the NEXT button.
Step5
- Adjust the air pressure to the recommended value by using the air
pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned.
Step12
- Then click on the NEXT button.
Appendix B 3D Trouble Shooting Guide
B-25
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of the air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area of the sensor is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S)
Error Code $6003 Link
Step Message
E - Can't close the ANC.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door..
Step3 - Check if the related sensor operates from the I/O Status of Diagnosis.
. Yes, the sensor operates normally. Step4
. No, the sensor does not operate normally. Step14
- Then click on the NEXT button.
Step4 - Check if the air pressure is lower than the recommended value.
. Yes, the air pressure is lower than the optimum pressure. Step5
. No, the air pressure maintains the optimum value. Step13
- Then click on the NEXT button.
Step5
- Adjust the air pressure to the recommended value by using the air
pressure control valve.
- Was air pressure adjustment successful?
. Yes, the air pressure is adjusted to the recommended value. Step6
. No, the air pressure does not go up even though the air pressure
control valve was turned.
Step12
- Then click on the NEXT button.
Step6 - Close the equipment door.
Step7 1. Press the RESET button.
2. Turn on the power for MOTOR.
2. Press the READY button.
- Then click on the NEXT button.
Step8 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
Samsung Component Placer CP-45F(V)/FS Operations Manual
B-26
3. Press the HOME START button.
- Then click on the NEXT button.
Step9 - Click on START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step10 - Click on START or CONTINUE on MMI.
Step11 - Press the START button to resume operation.
Step12
- Check the connecting condition of the air pressure hose and resume
operation.
Step13 - Check if there is any physical interference. Step6
- Then click on the NEXT button.
Step14 - Check the following and resume operation.
Check if there is any contaminant, such as grease, on the sensor.
Check if the sensor or power supply area of the sensor is normal.
(If the problem persists until after above steps have been taken, please
contact our C/S)
Error Code $2211 Link
Step Message
E - The right sensor of the Hole Fix is not sensed.
Step1 - Press the STOP button. (Stop the buzzer sound).
Step2 - Open the equipment door..
Step3 - Check the size, position, and direction of the PCB.
Is the Hole Fixer inserted properly in the right Fix Hole?
. Yes, the Hole Fixer is inserted properly. Step4
. No, the Hole Fixer is not inserted properly. Step11
- Then click on the NEXT button.
Step4 - Adjust the position of the Sensor Dog.
- Then click on the NEXT button.
Step5 - Close the equipment door.
Step6 1. Press the RESET button.
2. Turn on the power for MOTOR.
3. Press the READY button.
- Then click on the NEXT button.
Step7 1. Select the HOME mode by using the MODE button in the teaching box.
2. Turn off all the LEDs by using the AXIS button.
3. Press the HOME START button.
-Then click on the NEXT button.
Step8 - Click START or CONTINUE on MMI.
'START': starts operation with a new PCB.
Step9 - Click on START or CONTINUE on MMI.
Step10 - Press the START button to resume operation.
Step11 - Click on the BTU Down button in View->Manual Control of MMI.
- Then click on the NEXT button.
Step6 1. Remove the PCB after lowering the Backup Table.
2. Cancel the Hole Fixer.
3. Put the PCB.
4. Fit the Hole Fixer into the Fix Hole and secure it.
- Then click on the NEXT button. Step5
Error Code $2212 Link