3 Technical data and assemblie s Instruction manual SIPLACE TX 3.7 PCB conveyor system From software version 714.0 12/2020 148 3.7.5 Definition of PCB warp age 3.7.5.1 PCB warp age on the conveyor PCB warpage across the …
Instruction manual SIPLACE TX 3 Technical data and assemblies
From software version 714.0 12/2020 3.7 PCB conveyor system
147
3.7.4 IPC-Hermes-9852
IPC-HERMES-9852 is a communication protocol for SMT lines and can replace the IPC SMEMA
interface. This protocol allows you to transfer more information than previously via the IPC
SMEMA interface. This could be, for example:
– Unique board IDs
– Barcodes
– Conveyor speed,
– Board length and width
– Board thickness
– Transport clearance height
All this information can be transmitted along the whole line without interruption. See also the ad-
ministrator manual IPC-HERMES-9852, [item no.: 00198615-xx]

3 Technical data and assemblies Instruction manual SIPLACE TX
3.7 PCB conveyor system From software version 714.0 12/2020
148
3.7.5 Definition of PCB warpage
3.7.5.1 PCB warpage on the conveyor
PCB warpage across the direction of travel max. 1 % of the PCB diagonal, but not exceeding 2
mm.
3
PCB warpage in the direction of transport + PCB thickness < 5.5 mm. Bending up of board edge
max. 2.5 mm.
3
3
3
Fixed clamped edge
Movable clamping device
Printed circuit board
Conveyor side wall
Fixed clamped edge
Conveyor belt
PCB transport direction
Front board edge
Front board edge
Right conveyor belt
Left conveyor belt
PCB transport direction

Instruction manual SIPLACE TX 3 Technical data and assemblies
From software version 714.0 12/2020 3.7 PCB conveyor system
149
3.7.5.2 PCB warpage during placement
3
3
Changes in the surface position are automatically applied by the functions for learning the height.
3
3
PCB warpage up, max. 2.5 mm
PCB warpage down, max. 2.5 mm
PCB support
To avoid impairing the placement quality and speed, we recommend using a PCB support e.g.
Smart Pin Support so that the PCB warpage downwards does not exceed 0.5 mm.