00195760-0102_UM_D3_SR605_EN.pdf - 第113页

User Manual SIPLACE D3 3 Technical data for the machine From software version SR.605.xx 07/2008 EN Edition 3.5 Placement head 113 3.5.2.1 Description The 6-segment Collect&Pla ce head also works on the Collect&Pl…

100%1 / 364
3 Technical data for the machine User Manual SIPLACE D3
3.5 Placement head From software version SR.605.xx 07/2008 EN Edition
112
3
Fig. 3.5 - 4 6-segment Collect&Place head - Function groups, part 2
3
(1) Intermediate distributor board, beneath the cover
(2) Star drive - DR motor
(3) Z axis motor
(4) Valve adjustment drive
(5) C&P CO camera
User Manual SIPLACE D3 3 Technical data for the machine
From software version SR.605.xx 07/2008 EN Edition 3.5 Placement head
113
3.5.2.1 Description
The 6-segment Collect&Place head also works on the Collect&Place principle. The high-resolu-
tion digital component camera allows the 6-segment Collect&Place head to place components
with an edge length of up to 27 mm accurately and very quickly. It is therefore ideal for use with
products containing a large proportion of ICs. A considerable increase in output can be achieved
even in the main application range from PLCC 44 to QFP 208.
3.5.2.2 Technical data
3
6-segment Collect&Place head with high-resolution compo-
nent camera, type 29, 27 x 27, digital
Range of components
a
0201 to 27 x 27 mm²
Component specification
max. height
min. lead pitch
min. lead width
min. ball pitch
min. ball diameter
min. dimensions
max. dimensions
max. weight
8.5 mm
0.3 mm
0.15 mm
0.25 mm for components< 18 x 18 mm²
0.35 mm for components 18 x 18 mm²
0.14 mm for components < 18 x 18 mm²
0.2 mm for components 18 x 18 mm²
0.6 x 0.3 mm²
27 x 27 mm²
5 g
3 Technical data for the machine User Manual SIPLACE D3
3.5 Placement head From software version SR.605.xx 07/2008 EN Edition
114
Programmed power stage
1
2
3
4
5
Programmed set-down force [N]
2.4 ± 0.5
2.4 ± 0.5
3 + 1
4 + 1
5 + 1
Nozzle types 8xx, 9xx
X/Y accuracy
b
± 45 μm/3σ, ± 60 μm/4σ
Angular accuracy ± 0.2°/3 σ, ± 0.3°/4 σ
Component range 99.5%
CO camera type 29
Illumination level 5
Possible illumination level settings
256
5
a) Please note that the component range that can be placed is also affected by the pad geometry, the cus-
tomer-specific standards and the packaging tolerances.
b) The accuracy value was measured using the vendor-neutral IPC standard.