00195760-0102_UM_D3_SR605_EN.pdf - 第80页
2 Operational safety User Manual SIPLACE D3 2.7 Residual voltages and discharge times in the machin e From software version SR.605.xx 07/2008 EN Edition 80 2.7 Residual volt ages and discharge times in the machine If the…

User Manual SIPLACE D3 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.6 Safety equipment
79
2.6.5 Hand guard at the component trolley locations
WARNING 2
All locations must be equipped with feeder modules in order to guarantee operational reliability. If
there are not enough feeder modules available, unassigned locations should be fitted with a
hand guard (dummy feeder module). When a waffle-pack holder is set up, the remaining loca-
tions have to be protected again with a hand guard.
Fig. 2.6 - 9 Hand guard for component trolleys
2
(1) Hand guard for 1 location item no. 00116961-01
(2) Hand guard for 6 to 10 locations item no. 00116962-01
(3) Hand guard for 11 to 20 locations item no. 00116963-01

2 Operational safety User Manual SIPLACE D3
2.7 Residual voltages and discharge times in the machine From software version SR.605.xx 07/2008 EN Edition
80
2.7 Residual voltages and discharge times in the
machine
If the EMERGENCY STOP button is pressed or the placement system is switched off, the 250
VDC link voltage for the gantry axes and the 145 VDC link voltage for the star axes are reduced
to harmless residual voltages in a very short time.
WARNING 2
The machine is supplied with 3 x 200 VAC, 3 x 208 VAC, 3 x 230 VAC, 3 x 380 VAC,
3x400VAC or 3x415VAC ± 5%, 50/60Hz mains voltage. This means that some parts of the
system carry potentially lethal voltages - even when switched off at the main power switch. Incor-
rect handling of the machine can therefore result in death or severe injury or considerable dam-
age to equipment.
→ Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60
204, part 1).
→ The guards over the power supply unit and the axis unit must ONLY be opened by appropri-
ately qualified and trained personnel.
2
Fig. 2.7 - 1 Power supply unit
(1) Padlock with bolt in the cover
(2) Main power switch
(3) Power supply unit behind the cover
(4) Axis unit

User Manual SIPLACE D3 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.7 Residual voltages and discharge times in the machine
81
Fig. 2.7 - 2 Measuring points on the power supply unit
2
2.7.1 Operating voltages, residual voltages and discharge times after pressing
the EMERGENCY STOP button
2
2
Pins X11 and X13_1
measured to X12 (GND)
Voltage in
normal mode
Residual voltage
after EMERGENCY
STOP
Discharge
times
X11 + 250 VDC < 10 VDC 7 sec
X13_1 + 145 VDC < 10 VDC 50 sec
Pin X13_4
measured to pin X3_7 (-)
Voltage in
normal mode
Residual voltage
after EMERGENCY
STOP
Discharge
times
X13_4 + 40 VDC + 40 VDC -