User Manual SIPLACE D3 4 Setting up and commissioning From software version SR.605.xx 07/2008 EN Edition 4.3 Setting up the machine 209 4.3.7.4 Producing cable connections - extension kit on the PCB output side 4 4 4 4 4…

4 Setting up and commissioning User Manual SIPLACE D3
4.3 Setting up the machine From software version SR.605.xx 07/2008 EN Edition
208
→ Release the two horizontal tensioners (item 6 in Fig. 4.3 - 8, page 207).
CAUTION 4
Do not unscrew the three bottom screws straight away. Simply loosen them so that the side
plate does not fall off.
→ Detach the ground cable from the side plate.
→ Remove both doors (item 2 in Fig. 4.3 - 8
, page 207) from the extension kit (item 1).
PLEASE NOTE: 4
To avoid damage, we recommend that a second person helps to assemble the extension kit.
→ Set down the axis unit (item 8 in Fig. 4.3 - 8
, page 207) at the side of the machine in order to
make enough space to fit the extension kit (item 1 in Fig. 4.3 - 8
, page 207).
→ Make sure that the connecting cables to the axis unit are not too tight.
→ Lift the extension kit (item 1 in Fig. 4.3 - 8
, page 207) against the machine frame and position
it so that the assembly bracket lies on the assembly bar (item 7 in Fig. 4.3 - 8
, page 207).
CAUTION 4
Make sure that the extension kit does not collide with the hexagonal shaft of the PCB con-
veyor and the hexagonal shaft becomes bent.
→ Fix the extension kit using 4 fillister head screws M6x16 and the associated washers (item 3
in Fig. 4.3 - 8
, page 207).
4.3.7.3 Fitting the guide for the hexagonal shaft
→ On the single conveyor, fix one guide for the hexagonal shaft (item 8 in Fig. 4.3 - 7, page 205)
to the extension kit using two fillister head screws M6x16 and washers.
→ On the double conveyor, fix two guides for the hexagonal shaft (item 8 in Fig. 4.3 - 7
, page
205
) to the extension kit using two fillister head screws M6x16 and washers.

User Manual SIPLACE D3 4 Setting up and commissioning
From software version SR.605.xx 07/2008 EN Edition 4.3 Setting up the machine
209
4.3.7.4 Producing cable connections - extension kit on the PCB output side
4
4
4
4
4
Left-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
EMERGENCY STOP button
Start/stop button
X63/03020687 X63/03002526
Protective cover switch, location 3
X53/03020409 X53/03002528
Button for the component trolley docking unit, loca-
tion 3
X232/03021056 X232/03021053
Right-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
Start/stop button
Switch, PCB conveyor cover
X62/03020410 X62/03002525
Protective cover switch, location 2
X52/03006476 X52/03002527
Button for the component trolley docking unit, loca-
tion 2
X222/03021056 X222/03021052

4 Setting up and commissioning User Manual SIPLACE D3
4.3 Setting up the machine From software version SR.605.xx 07/2008 EN Edition
210
4.3.7.5 Fitting the grounding cable for the doors
→ Fix the two grounding cables for the doors (item 4 in Fig. 4.3 - 8, page 207) to the machine
frame as follows:
4
Fig. 4.3 - 9 Fitting the grounding cable
4
4
4
4
4
4.3.7.6 Checking and setting the protective cover switch
→ Check that the protective cover switch (item 7 in Fig. 4.3 - 10, page 211) is working correctly.
→ Adjust the protective cover switch if necessary (see service manual).
Hex nut M5
Spring washer M5, DIN 7980
Washer M5, DIN 125
Cable lug, annular
Contact washer