User Manual SIPLACE D3 4 Setting up and commissioning From software version SR.605.xx 07/2008 EN Edition 4.2 Infrastructure at the installation location 187 4.2.2.2 Compressed air connection on the machine 4 Fig. 4.2 - 1…

100%1 / 364
4 Setting up and commissioning User Manual SIPLACE D3
4.2 Infrastructure at the installation location From software version SR.605.xx 07/2008 EN Edition
186
4.2.1.2 Vibration limits
The machine is not sensitive to ground vibration, but the following vibration limits should still be
observed.
4
4
4
4
4
4.2.2 Compressed air supply
4.2.2.1 Checking the compressed air supply
Check that the compressed air supply conforms to the prescribed machine specifications (see ta-
ble in Section 3.2
, page 99).
PLEASE NOTE: 4
The document entitled "Network configuration (electrical and compressed air) for SMD systems
on the customer's premises", item no. 00191409-xx, describes the action that can be taken to
meet the required specifications.
Record the compressed air characteristics at the installation location.
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 4
Parameters Values
Third-octave spectral value
of the vibration speed 5 - 100 Hz
v < 250 μm/s
v
max
value on the time curve
v
max
< 1.5 mm/s
User Manual SIPLACE D3 4 Setting up and commissioning
From software version SR.605.xx 07/2008 EN Edition 4.2 Infrastructure at the installation location
187
4.2.2.2 Compressed air connection on the machine
4
Fig. 4.2 - 1 Compressed air line connection
(1) Stop valve in the "OPEN" position
(2) Manometer for the machine component supply pressure
Desired pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(3) Manometer for the gantry distributor supply pressure
Desired pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(4) Manometer for the bulk case feeder modules supply pressure
Desired pressure: 0.25 ± 0.05 MPa, 2.5 ± 0.5 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(5) Manometer for the input pressure
Desired pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(6) Compressed air filter
(7) Compressed air connection
(8) Hexagon socket head screw for fixing the pneumatic unit
4 Setting up and commissioning User Manual SIPLACE D3
4.2 Infrastructure at the installation location From software version SR.605.xx 07/2008 EN Edition
188
4.2.3 Main power supply
4
Fig. 4.2 - 2 Position of the power supply on the machine
4
(1) Lock
(2) Main power switch secured to prevent switching on again
(3) Cover