MEC-CP842-1.0E.pdf - 第51页
Basic Operation >> Changing the Conve yor Width MEC-CP842-1.0E 4-1 4. Basic Operation 4.1 Changing the Conveyor Wid th Point Conveyor width is adjusted simultan eously for the in-conveyor , XY -table, and out-con- …

The Machine >> Sensor Positions
3-28 MEC-CP842-1.0E
D2 Table (CP-842ME option)
C746M1025
X099
X098
X0A2
X095
X0A1
X0A1
X09D
X09C
X097
X096
X0A0
X09E
X09B
X09A
C746M1T07
X0CC
X0CE
X0CF
X0D2
X0D3
X0D4
X0D5
X0D6
X0D7
X0D8
X0D9
OUT-CARRIER FORWARD LIMIT PANEL CHECK
OUT-CARRIER FORWARD LIMIT CHECK
OUT-CARRIER RETRACT LIMIT CHECK
OUT-CARRIER RETRACT LIMIT CLAMP CHECK (FIXED RAIL)
OUT-CARRIER RETRACT LIMIT CLAMP CHECK (ADJUSTABLE RAIL)
OUT-CARRIER FORWARD LIMIT CLAMP CHECK (FIXED RAIL)
OUT-CARRIER FORWARD LIMIT CLAMP CHECK (ADJUSTABLE RAIL)
OUT-CARRIER RETRACT LIMIT UNCLAMP CHECK (FIXED RAIL)
OUT-CARRIER RETRACT LIMIT UNCLAMP CHECK (ADJUSTABLE RAIL)
OUT-CARRIER FORWARD LIMIT UNCLAMP CHECK (FIXED RAIL)
OUT-CARRIER FORWARD LIMIT UNCLAMP CHECK (ADJUSTABLE RAIL)
Sensor No.
SIGNAL NAME

Basic Operation >> Changing the Conveyor Width
MEC-CP842-1.0E 4-1
4. Basic Operation
4.1 Changing the Conveyor Width
Point
Conveyor width is adjusted simultaneously for the in-conveyor, XY-table, and out-con-
veyor. The conveyors should be adjusted to a width that permits smooth panel clamp-
ing and conveyance.
Procedure
1 Execute the necessary commands to link the XY-table to the in and out-convey-
ors. At the touch panel’s main screen, select the following commands: [Con-
veyor] - [Conveyor Width] - [Change Width], then press the START button.
2 Turn the handle on the out-conveyor to adjust the conveyor width until the
panel can be conveyed smoothly. First increase the conveyor width then reduce
it to 0.5~1.0 mm wider than the panel.
CAUTION
Before adjusting the conveyor width, check the back-up pin posi-
tions on the XY-table to prevent interference between back-up pins
and the adjustable rail.
C46M2001
Handle
C46M2002
W+(0.5~1.0)
(mm)
W
Panel

Basic Operation >> Changing the Conveyor Width
4-2 MEC-CP842-1.0E
3 Lower the XY-table.
4 Run a test panel through the machine, verifying that it is conveyed and clamped
smoothly.