Maintena nce >> Cleaning 5-16 MEC-CP842-1.0E 5.1.14 Carrier Rodless Cylinder (Monthly) Point Scattered chips, dust, and fine fibers adhere to the slide su rface of the rodless cyli nder used to drive the carrier . …

100%1 / 232
Maintenance >> Cleaning
MEC-CP842-1.0E 5-15
5.1.13 Oil Cooler Air Filter (Monthly)
Point
An air filter is attached to the exterior of the oil cooler unit. This filter should be
cleaned periodically to prevent damage to the oil cooler unit.
Procedure
1 Remove the acrylic cover from the top of the machine.
2 Hold the tab and lift the filter upwards to remove.
3 Clean the filter with a vacuum cleaner.
WARNING
Turn the main power off before performing this procedure.
C746M3012
<CP-842E> <CP-842ME>
Filter
Tab
Acrylic coverAcrylic cover
Maintenance >> Cleaning
5-16 MEC-CP842-1.0E
5.1.14 Carrier Rodless Cylinder (Monthly)
Point
Scattered chips, dust, and fine fibers adhere to the slide surface of the rodless cylinder
used to drive the carrier. As a result, it is necessary to perform periodic cleaning.
Procedure
1 Lightly wipe the slide surface of the rodless cylinder using a fine cloth. Remove
any dirt etc. that has accumulated between the ends of the slider surface and
the absorber holder.
2 Apply some grease to a fine cloth and wipe along the slider surface.
Note: Use Daphne Eponex No. 2 grease.
WARNING
Turn the main power off before performing this procedure.
C746M3013
Carrier cylinder
Absorber holder
Slider
Slide surface
Absorber holder
Maintenance >> Cleaning
MEC-CP842-1.0E 5-17
5.1.15 Nozzle Filter (Every 3 Months)
Point
The filter inside the shaft becomes dirty during the course of machine operation, and
should be replaced approximately every 3 months. If errors occur frequently for a spe-
cific nozzle, it is probable that the flow of air is being impeded by a dirty filter.
Procedure
1 Squeeze in the levers shown in the figure below, and carefully extract the filter.
Caution:
1. Do not apply excess force to the nozzle shaft.
2. Ensure that the filter is returned to the nozzle with the levers at the bottom.
2 Remove the pin from the filter assembly and replace both the filter and pin.
WARNING
Turn the main power off before performing this procedure.
C746M301
5
Filter Assy
C746M301
Pin
Filter