MEC-CP842-1.0E.pdf - 第83页

Maintenance >> Lubrication MEC-CP842-1.0E 5-23 5.2.4 Lubricating the XY -t able Caution:If the grease on the Y -axis screw cover drie s, the cover must be lubr icated, even if the cover is not due for periodic lubr…

100%1 / 232
Maintenance >> Lubrication
5-22 MEC-CP842-1.0E
Locations for Lubrication
Locations for lubrication are indicated in the illustrations using arrows and numbers.
White arrows are used to indicate locations that require lubrication of the surface.
Black arrows indicate that grease should be injected into a fitting with a grease gun
(pump).
Note: LM blocks that do not have a nipple can be lubricated by applying grease between the block
and the LM rail (bearing mechanism). The grease that adheres to the ball bearings and roll-
ers will be taken into the LM block and thereby lubricate the LM block.
Lubrication Checklist
A lubrication checklist is provided at the end of this chapter. This checklist should be
used as follows.
1 Check the lubrication points shown in the illustrations.
2 Mark each check box after lubricating.
(1)
(2)
C746M3016
LM rail
LM block
Maintenance >> Lubrication
MEC-CP842-1.0E 5-23
5.2.4 Lubricating the XY-table
Caution:If the grease on the Y-axis screw cover dries, the cover must be lubricated, even if the cover
is not due for periodic lubrication. Apply a thin layer of grease using a brush. Compressing
the screw cover by hand may result in injury. Furthermore, incorrect removal or installation of
the screw cover may result in damage to the machine.
Arrows in the illustration indicate lubrication points. Black arrows indicate that a
grease gun is required.
Caution:Always lubricate the X-axis/Y-axis ball screws using a grease pump to apply grease to the
fittings. Applying grease directly to the ball screws or compressing the covers by hand may
result in injury.
C746M3T03
Daphne Exponex No. 2
Multemp LRL3
Daphne Super Multi Oil 32
Daphne Exponex No. 2
Multemp LRL3
Daphne Super Multi Oil 32
Multemp SRL
Lubrication points
ScheduleTypes of lubricant
1
2
3
4
5
6
7
Every 3 months
Monthly
Every 3 months
Every 3 months
Monthly
Every 3 months
Monthly
X-axis LM block
X-axis ball screw
X-axis screw cover
Y-axis screw cover
Y-axis LM block
Y-axis ball screw
Z-axis ball screw
(1)
(1)
(4)
(4)
(2)
(5)
(7)
C746M3017
(6)
(3)
Maintenance >> Lubrication
5-24 MEC-CP842-1.0E
5.2.5 Lubricating the Conveyors
Arrows in the illustration indicate lubrication points. Black arrows indicate that a
grease gun is required.
Note: The out-conveyor should be lubricated in the same manner as the in-conveyor shown in the
figure above.
C746M3T04
Lubrication points
Schedule
Types of lubricant
8
9
10
Every 6 months
Every 6 months
Every 6 months
Ball screw
Lifter guide bar
LM block
Daphne Exponex No. 2
Daphne Exponex No. 2
Daphne Exponex No. 2
(8)
(8)
(10)
C746M3018
(9)
(10)