MEC-CP842-1.0E.pdf - 第67页

Maintenance >> Cleaning MEC-CP842-1.0E 5-7 5.1.6 Camera Glass (Weekly) Point The camera glass should be cl eaned once a week to en sure that a clear image is being acquired. This also contribut es to stable vision …

100%1 / 232
Maintenance >> Cleaning
5-6 MEC-CP842-1.0E
5.1.5 Nozzle Interior (Weekly)
Point
Because the part is held by vacuum through the nozzle, minute dust or glue particles,
etc., can build up inside the nozzle tube, causing clogging. Such clogging can reduce
the nozzle suction and cause problems when picking up parts. The nozzle tube should
be cleaned out weekly, or when clogging occurs.
Procedure
Use an appropriately sized drill bit to remove foreign matter from inside the nozzle
tube.
When cleaning is complete, check the drill bit to ensure that dirt from the nozzle has
not adhered to the tip.
Note: Jig AWPJ810* cannot be used for ø0.4 nozzles.
Caution
:
1. Take care to avoid bending the nozzle.
2. Take care to avoid dirtying the surface of the fluorescent sticker.
C746M3004
Nozzle
Drill bit
Fluorescent nozzle sticker
JIG No. AWPJ8100
Maintenance >> Cleaning
MEC-CP842-1.0E 5-7
5.1.6 Camera Glass (Weekly)
Point
The camera glass should be cleaned once a week to ensure that a clear image is being
acquired. This also contributes to stable vision processing and part pick-up.
Procedure
Use a soft brush (such as those used to clean camera lenses) to clean the camera glass.
If the glass is excessively dirty, then use a commercially available glass cleaner.
WARNING
Turn the main power off before performing this procedure.
CAUTION
Take care to not bend the nozzle.
C84PCA001E
%COGTCINCUU
Maintenance >> Cleaning
5-8 MEC-CP842-1.0E
5.1.7 Filter Regulator (Weekly)
Point
The air that flows through the system’s air lines should always be clean. A dirty filter
regulator makes it impossible to supply clean air, and can cause equipment failure.
Procedure
Be sure to turn the air supply off and to release the air pressure in advance.
1 Close the air inlet valve lever and cut the external air-supply.
2 Reduce the pressure in the air hose.
After disconnecting the air hose, return the valve lever slowly to the position
indicated in the illustration below to expel the air from the air inlet.
3 Close the valve lever again when the air has been fully expelled.
CAUTION
Turn the main power off before performing this procedure.
C746M3006
Valve lever
Close
C746M3007
Valve lever
Air
Air hose