5.2.10 Excercise: C&P20 P Head
1. During reference run the difference between open/close vacuum values for segment 2
is too low, what could be the possible reason?
A PRV is defective.
B Holding circuit vacuum is soiled.
C The nozzle soiled or wrong type.
D Holding circuit vacuum measurement board is defect.
2. Which of the following describes best the function of the component sensor?
A To measure the nozzle height.
B To monitor the presence and/or component height after pickup and before placement.
C To determine Z Axis movement.
D All of the above.
3. Which of the following is false?
A The function of the retract unit is to prevent the Z Axis from sliding down and getting dam-
aged after power off
B The Z Axis end signal is triggered by bottom light sensor, no matter what placement mode
for CPP Head.
C The function of the component camera is component recognition and to determine the exact
position of component on nozzle
D The function of the PRV is to supply vacuum and air kiss during Pickup/Place process.
4. What are the differences between C&P20 P and C&P20 M2
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………