00198168-02_Technical_Training_TX-Series_EN.pdf - 第22页

2 Machine Basic Overview 2.4 Machine Configuration 22 Technical Training SIPLACE TX-Series 10/2016 TX 2i Machine Configuration Two gantries with same head types: ● C&P20 P / C&P20 P camera type 23 or 41 ● CPP / C…

100%1 / 266
2 Machine Basic Overview
2.4 Machine Configuration
Technical Training SIPLACE TX-Series 10/2016 21
2.4 Machine Configuration
TX 1 Machine Configuration
One gantry with 1 head type:
CPP Head – camera type 30 and
stationary camera type 33 on location 1.
C&P20 P Head camera type 23 or 41
Twin Head stationary camera type 33 or
25
JTF-ML (only Location1)
Reject Tray (only Location1)
Table position:
Location 1: Outer
Location 2: Inner
Gantry upgrade to TX2 possible
Feeder Count With C&P20 P With CPP With Twin Head
Location 1 38 40 40*
Location 1 with JTF ML - 28 28
Location 2 38 40 40*
TX 2 Machine Configuration
Two gantries with same or different head
types possible:
C&P20 P / C&P20 P camera type 23 or 41
TH stationary camera type 25 or 33
/ CPP camera type 30
CPP / CPP camera type 30
CPP** / CPP** camera type 30 and
stationary camera type 33 on location 1
JTF-ML (only Location1)
Reject Tray (only Location1)
Table Position:
Location 1: Outer
Location 2: Inner
Feeder Count With C&P20 P With CPP With Twin Head
Location 1 38 40 40*
Location 1 with JTF ML - 28 28
Location 2 38 40 Not Applicable
*The right segment cannot reach 3 tracks on the left side of the table; the left segment cannot
reach 3 tracks on the right side of the table.
**The CPP Head has a low and a high installation position (with low position a stationary
component camera is not possible).
2 Machine Basic Overview
2.4 Machine Configuration
22 Technical Training SIPLACE TX-Series 10/2016
TX 2i Machine Configuration
Two gantries with same head types:
C&P20 P / C&P20 P camera type 23 or 41
CPP / CPP camera type 30
Table Position:
Location 1: Inner
Location 2: Inner
Other:
No stationary camera
No Tray units (JTF)
Feeder Count With C&P20 P With CPP
Location 1 38 40
Location 2 38 40
TX 2 micron 20/25 µm Machine Configuration
Two gantries with same or different head
types possible:
C&P20 M2 / C&P20 M2 camera type 41
CPP M_H_L / CPP M_H_L camera type
45
X-fiducial bar
No stationary cameras
JTF-ML on Loc.1
Note:
When JTF is used the CPP head must be
mounted in the high position.
Table Position:
EOL application
Location 1: Outer
Location 2: Inner
Feeder Count With C&P20 M2 With CPP M CPP M with JTF_ML
Location 1 38 40 28
Location 2 38 40 40
2 Machine Basic Overview
2.4 Machine Configuration
Technical Training SIPLACE TX-Series 10/2016 23
TX 2i micron 20/25 µm Machine Configuration
Two gantries with same head types:
C&P20 M2 / C&P20 M2 camera type 41
CPP M_L / CPP M_L camera type 45
X-fiducial bar
No stationary cameras
Table Position:
Speed application
Location 1: Inner
Location 2: Inner
Feeder Count With C&P20 M2 With CPP M
Location 1 38 40
Location 2 38 40
TX 2i micron 15 µm Machine Configuration
Two gantries with same or different head
types possible:
C&P20 M2 / C&P20 M2 camera type 41
CPP M_L / CPP M_L camera type 45
Stiffened lifting table
Basic pack vacuumtooling and vacuumtool
with Y-fiducial bar
X-fiducial bar
No stationary cameras
Table Position:
Speed application
Location 1: Inner
Location 2: Inner
Feeder Count With C&P20 M2 With CPP M
Location 1 38 40
Location 2 38 40