00198168-02_Technical_Training_TX-Series_EN.pdf - 第89页
5 Placement Heads 5.1 CPP Head Technical Training SIPLACE TX-Series 10/2016 89

5 Placement Heads
5.1 CPP Head
88 Technical Training SIPLACE TX-Series 10/2016
Room for Your Sketches and Notes

5 Placement Heads
5.1 CPP Head
Technical Training SIPLACE TX-Series 10/2016 89

5 Placement Heads
5.2 C&P20 P/M2 Head
90 Technical Training SIPLACE TX-Series 10/2016
5.2 C&P20 P/M2 Head
5.2.1 C&P20 P Head - Overview
5.2.1.1 Overview
1. Pressure control valve
2. Z Axis
3. Retract unit
4. Star motor
5. Air supply to holding circuit
6. Intermediate distributor
7. Component camera position
8. DP cooling Fan
9. DP control board
10. Component sensor
Features of C&P20 P Head
●
Can be used with pressurized air or vacuum pump (standard configuration).
●
Benchmark rate 39000cph.
●
Lower placement force at full speed.
●
Improvement of the usability and robustness.
●
Robust placement process of small components, C&P20 P head is fully capable to place
0201m.
●
Greater error tolerance during operation.
C&P20 M2 Head - Overview
1. Pressure control valve
2. Z Axis
3. Retract unit
4. Star motor
5. Air supply to holding circuit
6. Intermediate distributor
7. Component camera position
8. DP cooling fan
9. DP control board
10. Component sensor
C&P20 M2 differences
●
Optical the same but red handle
●
Star – resolution of the CP20M2 star is1000 digits / degree
●
DP –DPs controlled by C&P20 M2 firmware
●
Intermediate Distributor –C&P20 M2
●
Star, DP and Intermediate Distributor have own unique part numbers.