5 Placement Heads
5.1 CPP Head
Technical Training SIPLACE TX-Series 10/2016 75
5.1.7.2 Calibration Steps
1. Log on as Machine service (1-3). 2. Click Calibration (1).
Click Automatic calibration (2).
3. Under pull down menu Selection select
Calibration of fiducials, cameras and
heads.
4. Deselect Nozzle changer (1).
Click Next (2).
5. Select required Gantry (1).
Click Next (2).
6. Select required Locations and Place-
ments areas (1).
Click Next (2).
5 Placement Heads
5.1 CPP Head
76 Technical Training SIPLACE TX-Series 10/2016
7. Software checks preconditions and displays
status of necessary tools.
Click Start to continue.
8. Calibration has started.
9. Calibration has finished.
Click Accept to approve measurement.
5 Placement Heads
5.1 CPP Head
Technical Training SIPLACE TX-Series 10/2016 77
5.1.8 Analyse
5.1.8.1 Error General Information
Check Error Information from "Help", to define which kind of problem has occurred.
1. Error Number
2. Possible cause and solution
The main causes of error during production are:
Vacuum error
Z Axis problem
DP Axis problem
Nozzle change pick up/reject problem
Placement quality issue
Use the charts below during the training to assist with trouble shooting.