7 Conveyor System Room for Your Sketches and Notes 190 Technical Training SIPLACE TX-Series 10/2016 Room for Your Sketches and Notes

100%1 / 266
7 Conveyor System
7.7 Maintenance
Technical Training SIPLACE TX-Series 10/2016 189
7.7 Maintenance
Maintenance item for Conveyor system. For detailed information refer to the maintenance Job card.
Maintenance content Interval Requirement
Vacuum complete conveyor area All Workflows Cleaning wipe/vacuum cleaner
Recirculating ball screws and round shaft Workflow 3 Cleaning wipe, KM-wipe
Preserve the linear guidances Workflow 3
SIPLACE cleaning-tissue
Protective gloves latex
Clean the guide shafts Workflow 3 Cleaning wipe, KM-wipe
Clean the X-fiducial bar All workflows
Cleaning wipe
Protective gloves latex
TX micron 15μm:
Clean the -fiducial bar
All workflows
Cleaning wipe
Protective gloves latex
Lifting table statilizer Workflow 4
Ben 32
7.8 Excercise: Conveyor System
1. Which of the following statements is incorrect?
A Dual conveyor with outer fixed rail is the standard configuration for TX.
B Single conveyor is option for TX1.
C The conveyor system is controlled by two TSP420 control boards.
D The fixed rail is fixed by two screws, and it is possible to reconfigure.
2. What action is necessary after exchanging the lifting motor for TX?
A Adjust the belt tension for conveyor transport tooth belt.
B No action required.
C Calibrate the ZPC for the lifting motor.
D Calibrate the ZPC for lifting motor and the current value for lifting motor.
3. What needs to be calibrated after exchange of the vacuum tooling?
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
7 Conveyor System
Room for Your Sketches and Notes
190 Technical Training SIPLACE TX-Series 10/2016
Room for Your Sketches and Notes
7 Conveyor System
Room for Your Sketches and Notes
Technical Training SIPLACE TX-Series 10/2016 191