00198168-02_Technical_Training_TX-Series_EN.pdf - 第87页

5 Placement Heads 5.1 CPP Head Technical Training SIPLACE TX-Series 10/2016 87 5.1.10 Excercise: CPP Head 1. Which of the following is false regarding CPP Head? A Three placement modes possible: Collect & Place, Pick…

100%1 / 266
5 Placement Heads
5.1 CPP Head
86 Technical Training SIPLACE TX-Series 10/2016
Maintenance task Multistar CPP Interval Equipment required
Oiling the DP Driver Bearing Workflow 3
Multipette M4
Combitips advanced 0,1ml black
Cleaning wipe, KM-wipe
Klueberalfa DH 3-100, 50ml (black)
Cleaning sticks
Maintain the holding circuit Workflow 3
Multipette M4
Combitips advanced 10ml orange
Cleaning wipe, KM-wipe
Ultrasound device FA Bandelin 327
Ultrasonic Cleanser Alsar 25 NKF
Deionized distilled water
Compressed air
Maintain the PRV Workflow 3
Torque screwdriver ESD 0,1-0,6Nm
Wrench socket size 8-1/4"
POINT PLIERS 140mm OVAL
Screwdriver flathead
Indented cross blade PH1
O-Ring I3601 B-1,5X1,08-N-NBR70
Cleaning wipe, KM-wipe
Isopropanol
ISOFLEX Topas 5051 50ml ((green)
Compressed air
Cleaning sticks
Replacing the Filter Disks Workflow 3
Tweezers for filterdisc CPP
Filter disc cpl./CPP
Oiling the Star Bearing Workflow 3
Hexagon socket head CAP
screwdriver
Multipette M4
Combitips advanced 0,1ml green
Lubric.application tool star bearing
CPP
Cleaning wipe, KM-wipe
ISOFLEX Topas 5051 50ml ((green)
Cleaning the Component Sensor Workflow 3
Component-Sensor protectiv cover/
CPP
Isopropanol
Cleaning sticks
For detailed information refer to the maintenance Job Cards for the CPP Head.
5 Placement Heads
5.1 CPP Head
Technical Training SIPLACE TX-Series 10/2016 87
5.1.10 Excercise: CPP Head
1. Which of the following is false regarding CPP Head?
A Three placement modes possible: Collect & Place, Pick & Place and Mixed mode.
B With top placement performance the CPP_H: max. components height is 11.5mm and the
CPP_L: max. height components is 6 mm.
C The bottom light sensor is integrated into each DP driver for CPP.
D Holding circuit vacuum is always activated during placement.
2. Which description is correct regarding the CPP Head vacuum system?
A Vacuum pump is a standard component for holding circuit of CPP.
B Pressure Regulator Valve (PRV) supplies the pickup/placement and holding circuit with
vacuum/air kiss during the pickup/placement process.
C The holding circuit vacuum can be switch on/off by the valve block.
D All vacuum values can be measure by PRV.
3. One Base Adapter C&P board is used for CPP, and another Base Adapter with same
part no. is used for C&P20 P, nothing is required to be done if we exchange them.
True …………………………………………………………………………………………………
False …………………………………………………………………………………………………
4. What is the function of component sensor?
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
5 Placement Heads
5.1 CPP Head
88 Technical Training SIPLACE TX-Series 10/2016
Room for Your Sketches and Notes