5 Placement Heads 5.1 CPP Head Technical Training SIPLACE TX-Series 10/2016 53 5.1.2 Main Parts/Unit Overview 5.1.2.1 Star 1. Single Core Solution (SCS) 2. Holding circuit in center of star 3. DP drives 4. ED transmitter…

5 Placement Heads
5.1 CPP Head
52 Technical Training SIPLACE TX-Series 10/2016
5.1.1.2 Technical Data
Component spectrum Component camera
SST30
Stationary camera
SST33
Component camera
SST45
Component range 01005 to
27mmx27mm
0402 to
50mmx40mm
01005 to
15mmx15mm
Component height
(CPP_H)
Max. 8.5 mm C&P mode
Max. 11.5 mm in P&P and mixed mode
Component height
(CPP_L)
Max. 6 mm at max placement performance
Placement accuracy +/- 40 µm (3 sigma) with camera type 30
+/- 34 µm (3 sigma) camera type 33
+/- 15 µm (3 sigma) camera type 45 (only TX2i micron 15 µm)
Programmable set-down
force
1.0 - 10 N
Component weight Max. 4 g in C&P mode, mixed mode
Max. 8 g in P&P mode
Component cameras SST30 (01005 to 27 mm x 27 mm) Standard
SST33 (0402 to 50 mm x 40 mm)
SST45 (01005 to 15mmx15mm)
Note: TX micron has no stationary camera
Nozzle changer NC Base structure CPx / Short
Nozzle types Nozzle types 20xx and 28xx
For full specification refer to the user manual.
Machine Types
Machine X-Series (SW70x) SX Series X-Series S TX- Series
CPP X X X X
Configuration
Low installation height (CPP_L) or high installation height (CPP_H).
Note: High installation height (CPP_H) is not supported by TX2i micron, but supported by TX2
micron without JTF-ML.

5 Placement Heads
5.1 CPP Head
Technical Training SIPLACE TX-Series 10/2016 53
5.1.2 Main Parts/Unit Overview
5.1.2.1 Star
1. Single Core Solution (SCS)
2. Holding circuit in center of star
3. DP drives
4. ED transmitter 24V (contactless energy
transfer)
5. Fixture on rotor of star motor
6. Valve terminal/board
7. Star frame
●
The star consists of the star frame, on which the 12 DP drives are located, the control board
(Single Core Solution), the valve terminal and the E/D transmitter.
●
The holding circuit is in the center of the star.
Star Motor
A Exterior View
1. Lubricate position Star bearing
2. Stator Star Motor
3. Rotor Star Motor / Interface for fixing the
star frame
B Interior View
4. Reader head measuring system
5. Incremental measuring system
●
The motor functions contact free i.e. there is no wear and tear.
●
The head casing also serves as the motor casing.
●
The star motor is not a spare part and can not be replaced.

5 Placement Heads
5.1 CPP Head
54 Technical Training SIPLACE TX-Series 10/2016
5.1.2.2 DP Drive
1. Vacuum / Air kiss connection
2. Motor
3. The connector screwed to the SCS control
unit
4. Nozzle interface
5. Camera background (black) for DP drive
6. Mounting surface for screwing the linear
guide
7. Measuring system
●
The DP drive is responsible for turning the nozzles into the correct pickup position and the
component into the correct placement angle.
●
Vacuum and air blast to the nozzle are provided via the motor shaft of the DP Axis.
●
The complete DP drive can be replaced during service work.
1. Measuring system
2. Cushioning path for operating the light
barrier down
3. Light barrier down
DP Drive function
●
The DP drives are controlled by the SCS board, in accordance with the counter pulse and
nominal value (pickup angle, placement angle and correction angle after Vision).
●
The feedback about the position of the DC motor is monitored by an incremental measuring
system.
Light barrier bottom
●
Each DP drive has its own light barrier down sensor. When the Z Axis springs into place, the
sensor sends a signal to the axis controller board (MHCU).
●
The "light barrier down" signal is directly linked to the measurement signal of the Z Axis
incremental encoder.