00197195-02-UG SetupCenter 5.1_en.pdf - 第124页

Working with the Setup Center Application Next Setup in Setup Center Plausibility Check - Missing Refill 124 User Guide SIPLACE Setup Center 5.1 ► Select the recipe for the next setup from the Pro duction Schedules or Se…

100%1 / 196
Working with the Setup Center Application
Plausibility Check - Missing Refill Next Setup in Setup Center
User Guide SIPLACE Setup Center 5.1 123
7.6 Next Setup in Setup Center
The next setup can be conveniently configured using the Next Setup function in Setup Center. This
shows the status of the next setup, such as:
Status display for the next setup (based on the actual setup in the line).
Which components have been set up or are still missing from the next setup?
Which components are configured on the wrong location? (for Random Setup Within a Table).
Which spare tracks and multiple setup components are in the line.
Which components will not be used in the next setup?
Feeder LED control settings.
TIP: this function allows you to print a delta list of materials.
This provides a clear analysis for a delta setup.
View - Open next setup
Start SIPLACE Setup Center.
Select the Next Setup icon in the Setup Center main menu.
⇨ The Choose Next Setup dialog box will open
Icon Action Meaning
1 Yes - The scanning of the refilled
packaging unit was forgotten.
The packaging unit data in the data base will not be
changed. The refill can now be completed.
2No The scanning of the refilled pack-
aging unit was not forgotten.
The gray zone will be removed from the packaging
unit. The packaging unit is torn down and must be
scanned again.
Step 3:
You will be prompted to scan the set-up or refilled
packaging unit.
Finally, the track is reactivated.
NOTICE
If, during line conversion, you need to tear down all components and re-configure the next set-
up, you will not necessarily need this function. You do not have to apply the "Next Setup" func-
tion in Setup Center in order to use Random Setup.
Working with the Setup Center Application
Next Setup in Setup Center Plausibility Check - Missing Refill
124 User Guide SIPLACE Setup Center 5.1
Select the recipe for the next setup from the Production Schedules or Setups tabs.
⇨ The main Next Setup view will open.
NOTICE
The green highlighted recipe in the "Choose Next Setup" dialog box shows the current recipe
set at the line. This helps the user find the current position and select the next recipe with the
next setup.
Working with the Setup Center Application
Plausibility Check - Missing Refill Next Setup in Setup Center
User Guide SIPLACE Setup Center 5.1 125
Icons and their meanings
List box: Random Setup Mode
List box Feeder LED Control
Icon/meaning Meaning
The component is already at the line and does not need to be configured.
The component also needs to be configured on a spare track.
(red)
The component is missing at the line and needs to be configured.
(orange)
The component is missing from this location but is configured at another location.
The component has been wrongly configured at this location and should instead
be set up at another location. The correct location can be found in the Optimized
Location column.
The component is unknown.
-- The component will not be needed in the next setup and can be torn down at setup
changeover.
Correlation The actual location of the configured components at the line is compared with the
location of the optimized setup.
Setting Random Setup – Within a Table:
No value
Setting: Random Setup – On the Line:
The component is already at the line but on a random table and track.
The component is already on the correct table of the line but on a random track.
The component is on the correct table and on the correct track.
The component is already on the right track and has been configured and verified
at the station, according to the optimization specifications in SIPLACE Pro.
Designation Meaning
Random Setup Within
a Table
When you open the Next Setup view, the download settings are adopted from
the Line Control GUI and displayed. The setting can be changed for test pur-
poses, for example to check the completeness of the components. Changing
these settings has no impact on the settings in the Line Control GUI.
Random Setup – On
the Line
Designation Meaning
Station The status of the feeder LEDs is controlled only by the station.
Preview The status of the feeder LEDs is controlled by the station and by Setup Center.
The station for feeders used in the current setup.
Setup Center for feeders which have already been configured for the next
setup.
Changeover The status of the feeder LEDs is only controlled by Setup Center in relation to
the next setup. Setup Center thereby excludes LEDs for the feeders which are
not required for the next setup. This enables the user to tear down feeders no
longer required.