Setting System Components Station Software Settings (from Version 70x) Component Level Indicator 64 User Guide SIPLACE Setup Center 5.1 Disabling the setup verification ► Select the Settings button (1) . ► Select the but…

Setting System Components
Setup Verification at the Station Station Software Settings (from Version 70x)
User Guide SIPLACE Setup Center 5.1 63
4.2.1.1 Checking the Connection Status
Check the connection status for your Setup center application with the station software.
Checking the connection status
► Select the Settings button (1).
► Select the Connected clients button (2). Section (3) will show the active connections.
► Select a connection in section (3) to view its details in section (4).
► For details, refer to the station software Online Help.
4.2.1.2 Enabling/Disabling the Setup Verification
As a default, the machine is set in forced setup verification mode.
If you still want to disable forced setup verification in the station software, this can be done in the machine
options. In order to do this, at least operator level "Service (customer)" must be set.
WARNING
Only disable the setup verification at the station computer in emergencies
If you want to disable the setup verification, always do this in SIPLACE Pro. the setting in the
station software may only be used in absolute emergencies, as the station software, SIPLACE
Pro and Setup Center systems will no longer be synchronized otherwise.

Setting System Components
Station Software Settings (from Version 70x) Component Level Indicator
64 User Guide SIPLACE Setup Center 5.1
Disabling the setup verification
► Select the Settings button (1).
► Select the button shown at (2).
► Enable the Skip Setup Verification checkbox (3).
4.2.2 Component Level Indicator
With the setup verification data, SIPLACE Setup Center can supply the original packaging unit size
(component quantity) for the component level indicator. Then throughout the entire placement process
the component level indicator shows when individual feeders are running empty and need to be refilled.
When the threshold values in the Setup Center settings are activated, a warning is given to indicate that
a track is going to run empty. See "3.4.4 Threshold Settings" [ ➙ 37].
If the operator reacts promptly to this warning, the machine can be prevented from coming to a standstill
as a result of a "Track empty" error.
The main view of the station shows whether the component level indicator thresholds have been reached
or tracks have been run empty. This is displayed by a change in the color of the buttons Setup or Com-
ponent Level Indicator.
NOTICE
Defining the forced setup verifications settings
There are currently no technical means for SIPLACE Setup Center to determine whether forced
setup verification for the machine is enabled or disabled.
For this reason it is always necessary to ensure manually that the settings for setup verification
are the same at the station and in Setup Center!

Setting System Components
Component Level Indicator Station Software Settings (from Version 70x)
User Guide SIPLACE Setup Center 5.1 65
Main window
1. Setup button
2. Component Level Indicator button
Setup button Description
An error has occurred but production can still continue.
▪ The component level indicator check is enabled and a low component level
has been detected for one feeder.
An error has occurred and production can not continue.
▪ A feeder for which the component level indicator check has been enabled has
been run empty.
Component Level
Indicator button
Description
An error has occurred but production can still continue.
▪ The warning threshold for low component level has been undershot for one
feeder.
▪ An error has occurred at one feeder which is required for the current setup.
▪ A feeder for which the component level indicator check has been enabled has
been run empty.