00193892-0402_AI_FeederCoverFlap_DE+EN.pdf - 第58页
Assembly instructions Feeder cover flap, SI PLACE HF-series / X-series / D3 05/2009 Edition 58 2.6 Assembly Feeder cover flap (old version) 2.6.1 Overview These flaps a re not available any more. This manual is only nece…

Assembly instructions Feeder cover flap, SIPLACE HF-series / X-series / D3
05/2009 Edition
57
: Put a feeder on the outer left track and the outer right track and on the middle of the
changeover table.
: Adjust the height of the feeder protective plate with the left and the right headless set screw,
so that the distance between the bottom of the plate and the highest point of the feeder is about
1mm. The plate must not hit the feeders. Fix the screws with the screw nuts. Secure the screws
afterwards with screw locking paint.
2
2
: Repeat the described work steps at all locations where Feeder cover flaps should be installed.
2
: Turn on the machine and check the correct function of the protective plates.
: Before you execute a reference run, push the gantry carefully across the plate to make sure,
that there is enough space between the nozzle and the plate.
: Calibrate the nozzle changer and the nozzle removal unit.
2
protective
plate
distance between plate and
feeder should be about 1 mm
highest point of the feeder
(here a 2x8mm S feeder)
Assembly instructions Feeder cover flap, SIPLACE HF-series / X-series / D3
05/2009 Edition
58
2.6 Assembly Feeder cover flap (old version)
2.6.1 Overview
These flaps are not available any more. This manual is only necessary for a spare parts assembly.
The feeder cover flap is assembled in the same way on
both sides of the machine, only the other
way around. The manual shows photographs of both sides. 2
2.6.2 Restriction
The “Feeder Protection SIPLACE HF” can not be used in conjunction with the 6-nozzle revolver
head and nozzle types 820, 821, 921. When these short nozzles are used the segment touches
the protection plate before the nozzle touches the part in the pocket. 2
2.6.3 Tools and consumables required
– Set of hexagon socket spanners
– Caliper gauge
– Power drill or cordless screwdriver
– Metal drill bit (5 mm)
– Counterbore (5 mm at the tip / 12 mm at the shaft)
– Rose bit
– Deburrer
Additionally for HF-series up to A-001: 2
– Drilling gauge (item no.: 03033639-01)
Additionally for HF-series from A-001 / X-series: 2
– Drilling gauge (item no.: 03011814-01)

Assembly instructions Feeder cover flap, SIPLACE HF-series / X-series / D3
05/2009 Edition
59
2.6.4 Preparatory work
: Open the protective cover of the relevant gantry.
: Push the gantry out of the component table area until it is over the PCB feeder area.
: Dock the component trolleys out of the placement machine.
: Switch the placement machines off at the main switch.
2.6.5 Assembly for SIPLACE HF-series (up to A-001)
: Loosen the screws on the cover over the connections and remove the cover.
2
2
2
2
2
2
2
2
2
2
2