3OM-1751 1-62 1303-001 5.14 "Noz Incln" Window The teaching for the offset data to correct the head nozzle inclination is performed. [1] [2] F3A45 [1] T eaching Data Display Section Displayed are the teaching d…

3OM-1751
1-611303-001
[Save] button
When this button is pressed, the teaching results are saved.
•
Automatic Teaching Procedure
Procedure
(1) Select the nozzle stocker (1 or 2) for which the teaching is performed.
(2) Press the nozzle stocker selection button [NST-1] or [NST-4] to select the
nozzle stocker for which the teaching is performed.
(3) Press the [Teach Start] button.
•
When the teaching is started, the start conditions are checked.
•
The teaching results are displayed in the "After" data boxes in the
"Teaching Data" display area.
•
When any recognition error occurs during the teaching operation or the
[STOP] button is pressed on the operation penal, the machine is stopped
temporarily. In this case, re-start is available.
•
During this temporary stop mode, the selection of any other menu item is
unavailable.
When the teaching is completed, the designated head returns to the home
position automatically.
(4) Press the [Save] button.
(When this button is pressed, the teaching results are saved.)
5.13 "Noz Stk Pos" Window

3OM-1751
1-621303-001
5.14 "Noz Incln" Window
The teaching for the offset data to correct the head nozzle inclination is performed.
[1]
[2]
F3A45
[1] Teaching Data Display Section
Displayed are the teaching data items for the nozzle in the designated head.
[2] Teaching Procedure Display Area
Displayed are the buttons to be used for the teaching operations.
Select Head
The buttons showing the head positions are displayed as images.
Select the head corresponding to the nozzles for which the teaching is
performed.
Note
The window can be changed over using the tabs in the window.
[Noz All] button
When pressed, the teaching operation for all the nozzles is performed.
[Noz] button
Designate the nozzle to be taught in this area.
When the [Noz] button is selected and [Noz No] is pressed, the input window
appears.
Graphic
Development
5.14 "Noz Incln" Window

3OM-1751
1-631303-001
[Teach Start] button
When pressed, this button executes the teaching operation.
[Save] button
When this button is pressed, the teaching results are saved.
•
Teaching Jig
For the head/nozzle inclination offset teaching, the QFP glass jig JG-0188
(KYB-M381P-00) is used.
•
Jig Pick-up Nozzle
For the pick-up of the QFP glass jig, the jig nozzle (standard equipment) or the
normal vacuum nozzle HV19C is used.
•
Teaching Procedure
Procedure
(1) Before the teaching operation, change the nozzle to the jig nozzle and setup
the QFP glass jig in the jig setup position over the component recognition
camera.
(2) Select the head (1 or 2) and nozzle for which the head/nozzle inclination
teaching is performed.
(3) Press the [Teach Start] button.
(The head/nozzle inclination offset teaching will be executed.)
•
When the teaching is started, the start conditions are checked.
•
During this temporary stop mode, the selection of any other menu item is
unavailable.
When the offset teaching is completed, the designated head returns to the
home position automatically.
The teaching results are displayed in the "Head/Noz Incln Offset" Display
Area.
(4) Repeat the steps (1) through (3) to teach the nozzles for which the inclination
teaching operation is required.
(5) When the teaching operation is completed, remove the QFP glass jig.
(6) Press the [Save] button.
(When this button is pressed, the teaching results are saved.)
5.14 "Noz Incln" Window