3OM-1751-002w_G5S.pdf - 第208页
3OM-1751 2-40 1303-001 [4] Hd TumAng. Axis The set parameters are used to adjust the angular deviation of the line connecting the center of Nozzle No.1 and the position between the Nozzle Nos. 8 and 9 at the head rotatio…

3OM-1751
2-391303-001
[3] Head Pivot Point
The set parameters are used to adjust the deviations in the design value
between the head rotational center and the center of the PEC recognition
camera.
Xm-Ym :
Xm(+)
Ym(+)
Head Pivot Point
Center of PEC Recognition
Camera
Pm. Machine Reference
Coordinate Origin
Center of PEC Recognition Camera
Head Pivot Point
Machine Reference
Coordinate System
F3B38
2.5 "Head" Window

3OM-1751
2-401303-001
[4] Hd TumAng. Axis
The set parameters are used to adjust the angular deviation of the line
connecting the center of Nozzle No.1 and the position between the Nozzle
Nos. 8 and 9 at the head rotational Z-phase position based on the machine
coordinate reference.
When the line connecting the center of Nozzle No. 1 and the position
between the Nozzle Nos. 8 and 9 at the head rotational Z-phase position, is
tilted clockwise in the machine reference X/Y coordinate system, a plus sign
must be afxed to the offset value.
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
Xm(+)
Ym(+)
DD Motor Z-Phase
Stop Position
DD Motor Z-Phase
Stop Position
DD (+)
DD (+)
Head Rotational Angle Offset
Head Rotational Angle Offset
Pm. Machine Reference
Coordinate Origin
Xm-Ym :
Machine Reference
Coordinate System
F3B39
[5] NL Origin
The set parameters are used to correct the deviations between the nozzle U/D
mechanism and the nozzle roller caused while the NL axis is rotating.
[6] Noz Choice Axis
The set parameters are used to adjust the angular deviations between the
head rotational and nozzle selection axes.
[7] Flow Threshold
These parameters are used to judge the component presence/absence using
the multi-functional head ow sensor.
2.5 "Head" Window

3OM-1751
2-411303-001
2.5.8 "Vacuum Timing" Tab Sheet
[1] [2] [3] [4]
F3B40
[1] OFF [sec]
The specied parameter is used to adjust the timing to turn the vacuum off
while the NL-axis is descending for component placement.
When "+0.000" is specied in the "OFF" text box, the vacuum is turned off
when the NL-axis has reached 10 ms away from the bottom arrival point.
Base on the point 10 ms away from the NL-axis bottom arrival point, a plus
value in the "OFF" text box means that the timing to turn off the vacuum will
be delayed. A minus value means that the timing will be quickened.
2.5 "Head" Window
Graphic
Development