00198442-01_UM_TX-V2_EN.pdf - 第108页
3 Technical data and assemblies User manual SIPLACE TX V2 3.5 Placement head From software version 711.1 04/2018 108 3.5.1.1 Overview 3 3 Fig. 3.5 - 1 SIPLACE SpeedSt ar - overview (1) Connection for the holding cir cuit…

User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.5 Placement head
107
3.5 Placement head
3.5.1 SIPLACE SpeedStar C&P20 P2
The SIPLACE TX uses the SIPLACE SpeedStar C&P20 P2 for top placement performance.
3
CAUTION
Always take hold of the handle to push the placement head
The placement head may only be moved by pushing manually against the handle provid-
ed.

3 Technical data and assemblies User manual SIPLACE TX V2
3.5 Placement head From software version 711.1 04/2018
108
3.5.1.1 Overview
3
3
Fig. 3.5 - 1 SIPLACE SpeedStar - overview
(1) Connection for the holding circuit of the vacuum pump
(2) "Intermediate distribution board" (under the cover)
(3) Handle
(4) Star motor
(5) DP drive
(6) Nozzle
(7) Pressure control valve
(8) Z motor (linear motor)
(9) Return cylinder
(5)
(1)
(7)
(2)
(3)
(4)
(6)
(8)
(9)

User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.5 Placement head
109
3.5.1.2 Technical data for SIPLACE SpeedStar (C&P20 P2)
3
SIPLACE SpeedStar(C&P20 P2)
With component camera type 48
Component range
*a
*)a Please note that the placeable component range is also affected by the pad geometry, the customer-
specific standards, the component packaging tolerances and the component tolerances.
0.12 mm x 0.12 (0201 metric) to 2220, Melf, SOT, SOD, Bare-
Die, Flip-Chip
Component spec.
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
2 mm
*b
/ 4 mm
70 µm
30 µm
100 µm
50 µm
0.12 mm x 0.12 mm
8.2 mm x 8.2 mm
1 g
*)b Only 2 mm possible for SIPLACE TX2i.
Programmable set-down
force
Touchless Placement, 1.3 N ± 0.5 N (standard)
0.5 N - 4.5 N
Nozzle types 60xx
X/Y accuracy
*c
*)c The accuracy values fulfill the conditions in the SIPLACE scope of supply and services.
± 25 µm/3σ
Angular accuracy ± 0.5° / 3σ
Illumination level 5