00198442-01_UM_TX-V2_EN.pdf - 第112页

3 Technical data and assemblies User manual SIPLACE TX V2 3.5 Placement head From software version 711.1 04/2018 112 3.5.3.5 Frequency converter (optional) For details, re fer to the assembly instructions for this option…

100%1 / 304
User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.5 Placement head
111
3.5.3.2 Safety instructions for vacuum pumps
3
3.5.3.3 Description
Only the SIPLACE SpeedStar can be operated with the vacuum pump. In the SIPLACE TX V2,
the default configuration is a SIPLACE SpeedStar with vacuum pump.
There are a maximum of two SIPLACE SpeedStar heads and one vacuum pump.
When operated with a vacuum pump, the compressed air consumption for the SIPLACE Speed-
Star is reduced considerably. The running costs will fall according to the energy costs incurred.
The vacuum pump is switched on and off with the main switch of the placement machine.
3
3
3.5.3.4 Maintenance instructions
Observe the additional maintenance instructions for the vacuum pump.
Read the relevant section in the maintenance manual for your placement machine.
WARNING
Please observe the safety instructions in the vacuum pump user manual supplied.
If you use a frequency converter to operate the vacuum pump, you should take a
higher leakage current into account. The operator must observe the installation reg-
ulations which result from this (a second protective (earth) conductor may be re-
quired).
PLEASE NOTE
The vacuum pump is NOT approved for operation in the clean room for ISO class 7.
PLEASE NOTE
The compressed air consumption values can be found in section 3.2.3
, page 99.
3 Technical data and assemblies User manual SIPLACE TX V2
3.5 Placement head From software version 711.1 04/2018
112
3.5.3.5 Frequency converter (optional)
For details, refer to the assembly instructions for this option.
3
If the frequency converter is present, you must attach the warning label "high leakage current" at
location 1.
3
Fig. 3.5 - 3 Warning label "High leakage current", item no. 03155631-xx
CAUTION
The frequency converter may only be take into operation by qualified personnel!
The electrical connection and taking into operation of the frequency converter may only
be conducted by specifically qualified personnel.
User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.5 Placement head
113
3.5.4 SIPLACE MultiStar CPP
3
3
Fig. 3.5 - 4 SIPLACE MultiStar - front view, function groups part 1
(1) Handle
(2) Star with 12 segments
(3) Segment with integrated DP drive
CAUTION
Always take hold of the handle to push the placement head
The placement head may only be moved by pushing manually against the handle provid-
ed.
(2)
(3)
(1)